The DC-2/MC-1 includes 8 custom characters that are defined to display increments of a display block.
(i.e. Volume Bar) The custom characters are ASCII character codes 08 - 0F(hex). The codes are used as
follows:

'08' - left 1 bar
'09' - left 2 bars
'0A' - left 3 bars
'0B' - left 4 bars
'0C' - Full Cell
'0D' - Underscore
'0E' - right 3 bars
'0F' - not in use

7.1.3.3 HOST Response

The DC-2/MC-1 does not look for any response from the HOST.

7.1.4 Parameter Change Notification

DC-2/MC-1 will transmit predetermined parameter change notifications. If a parameter value is changed
due to any user action or system action the DC-2/MC-1 will transmit the current value of the parameter that
is changing.

7.1.4.1 Notification Packet Description

Application Header:
Command

DC_PARAM_CHG_MSG

0x04

Data Count

2

0x02

Application Data:
Data[0]

ParamId

nn

Data[1]

Value

nn

7.1.4.2 Data Description

ParamId:

DataType:

Unsigned 8 bit integer

Max:

Set by the System Parameter Count in the “Unit Configuration Packet”.

Value:

The Current Value for this system parameter.

Data Type:

Unsigned 8 bit integer

Max:

Set by the Max Value per the System Parameter Definition response

Packet for the Parameter Id of this packet.

7.1.4.3 HOST Response

The DC-2/MC-1 does not look for any response from the HOST.

7.1.4.4 Supported System Parameters

The following parameters will be supported by this Parameter Change Notification:

Parameter DC-2/MC-1 Parameter Name
Current Effect

PROGRAM

Mute

MUTE

System Volume

VOLUME

Balance

LR_BALANCE

Input Selection

INPUT

Record/Zone 2 On/Off

RECORD_ENABLED

Zone 2 Volume

Z2_VOL