7.3.3.3 DC-2/MC-1 Response

The KeyCode is processed as a valid IR code. No acknowledgment will be sent from DC-2/MC-1.

7.3.3.4 Data Validation

The KeyCode data will be verified as a legal IR code. If the Code is not valid the DC-2/MC-1 will not
respond.

7.3.4 Get DC-2/MC-1 Unit Configuration

Request to DC-2/MC-1 for it’s current unit configuration. DC-2/MC-1 will respond with “Unit
Configuration Packet”. The HOST should use this information to determine if any information saved by the
HOST is current.

7.3.4.1 Command Packet Description

Application Header:
Command

DC_CMD_GET_CONFIG

0x15

Data Count

0

0x00

Application Data:

N/A

7.3.4.2 DC-2/MC-1 Unit Configuration Response Packet

Application Header:
Command

DC_RESP_UNIT_CONFIG

0x80

Data Count 25

0x19

Application Data:
Data[0]

ProductId

nn

Data[1]

Software Type

nn

Data[2]

Software Level

nn

Data[3]

Software Major Revision

nn

Data[4]

Software Minor Revision

nn

Data[5]

Protocol Major Revision

nn

Data[6]

Protocol Minor Revision

nn

Data[7]

Total Number of System Parameters

nn

Data[8]

Total Number of Effects

nn

Data[9]

TimeStamp[0]

ch

Data[10]

TimeStamp[1]

ch

Data[11]

TimeStamp[2]

ch

Data[12]

TimeStamp[3]

ch

Data[13]

TimeStamp[4]

ch

Data[14]

TimeStamp[5]

ch

Data[15]

TimeStamp[6]

ch

Data[16]

TimeStamp[7]

ch

Data[17]

TimeStamp[8]

ch

Data[18]

TimeStamp[9]

ch

Data[19]

TimeStamp[10]

ch

Data[20]

TimeStamp[11]

ch

Data[21]

TimeStamp[12]

ch

Data[22]

TimeStamp[13]

ch

Data[23]

TimeStamp[14]

ch

Data[24]

TimeStamp[15]

0x00