TimeStamp:

Is a null terminated ASCII text string describing the build date and time of the
current ROM. The Format of this text string is:
“yy/mm/dd(sp)hh:mm”
yy- is the last two digits of the year (i.e. year 1999 = 99, year 2000 = 00)
mm - is the month
dd- is the day
(sp) - is an ASCII space character (0x20)
hh - is the hour
mm - is the minute

7.3.5 Get System Status

Request to DC-2/MC-1 for it’s current system status. DC-2/MC-1 will respond with “System Status
Packet”.

7.3.5.1 Command Packet Description

Application Header:
Command

DC_CMD_GET_SYS_STATUS

0x16

Data Count

0

0x00

Application Data:

N/A

7.3.5.2 System Status Response Packet

Application Header:
Command

DC_RESP_SYS_STATUS

0x81

Data Count

10

0x0A

Application Data:
Data[0]

System Volume

nn

Data[1]

Current Input

nn

Data[2]

Current EffectId

nn

Data[3]

Current Input Sample Rate

nn

Data[4]

Current Input Format

nn

Data[5]

Mute Active

nn

Data[6]

Effect Bypass Active

nn

Data[7]

Left/Right Balance

nn

Data[8]

Front/Back Balance

nn

Data[9]

Video Synch

nn

7.3.5.3 Data Description

System Volume:

Data Type:

Unsigned 8 bit integer.

Maximum Value:

92

Conversion:

0 = -80 dB
92 = +12 dB

Current Input:

Data Type:

Unsigned 8 bit integer.

Definition:

Appendix D Input Id’s

Current EffectId: