Command packet description, Record/zone2 status response packet, Data description – Lexicon DC-2 User Manual

Page 16: Get system parameter definition

Advertising
background image

Lexicon, Inc.
DC-2/MC-1 Serial Communications Protocol

Printed on: 10/19/00

16 of 44

Application Header:
Command

DC_CMD_GET_REC_STATUS

0x17

Data Count

0

0x00

Application Data:

N/A

7.3.6.2 Record/Zone2 Status Response Packet

Application Header:
Command

DC_RESP_REC_ZONE2_STATUS 0x82

Data Count

5

0x05

Application Data:
Data[0]

Zone2 Volume

nn

Data[1]

Assigned Input

nn

Data[2]

Zone2 Mute Active

nn

Data[3]

Record Active

nn

Data[4]

Zone2 Balance

nn

7.3.6.3 Data Description

Zone2 Volume:

Data Type:

Unsigned 8 bit integer.

Maximum Value:

92

Conversion:

0 = -80 dB
92 = +12 dB

Assigned Input:

Indicates the input that is currently assigned for the record/zone2 outputs.
Data Type:

Unsigned 8 bit integer.

Definition:

Appendix D Input Id’s

Zone2 Active:

Data Type:

Boolean.

TRUE:

Zone2 Outputs are active.

FALSE:

Zone2 Outputs are not active.

Record Active:

Data Type:

Boolean.

TRUE:

Digital Record Output is active

FALSE:

Digital Record Output is not Active.

Zone 2 Balance:

Data Type:

Unsigned 8 bit integer.

Maximum Value:

32

Conversion:

0 = Left
32 = Right

7.3.7 Get System Parameter Definition

There are two ways to request a DC-2/MC-1 system parameter definition. The first is by Parameter Id and
the second by parameter name. DC-2/MC-1 will respond with “System Parameter Definition Packet”.

7.3.7.1 Get System Parameter Definition by Id Command Packet

Error! Not a valid link.

7.3.7.2 Data Description

ParamId:

DataType:

Unsigned 8 bit integer

Advertising