Data validation, Set system volume, Command packet description – Lexicon DC-2 User Manual

Page 25: Data description, Dc-2/mc-1 response, Set main balance

Advertising
background image

Lexicon, Inc.
DC-2/MC-1 Serial Communications Protocol

Printed on: 10/19/00

25 of 44

The Effect Id must be a valid Effect Id. If it is not the DC-2/MC-1 will respond with a NAK packet and
error code DC_ERR_ INVALID_EFFECT_ID. If an invalid string is passed, DC-2/MC-1 will ignore the
command and transmit a DC_NAK command with an error code DC_ERR _INVALID_DATA.

7.3.18 Set System Volume

Commands DC-2/MC-1 to set the system volume with the value in this packet.

7.3.18.1 Command Packet Description

Application Header:
Command

DC_CMD_SET_SYS_VOLUME

0x21

Data Count

1

0x01

Application Data:
Data[0]

Value

nn

7.3.18.2 Data Description

Value:

Data Type:

Unsigned 8 bit integer.

Max:

92

Conversion:

0 = -80 dB
92 = +12 dB

7.3.18.3 DC-2/MC-1 Response

The DC-2/MC-1 will assign the value from the packet to the system volume.

7.3.18.4 Data Validation

If a value is passed that exceeds the maximum value of that parameter the DC-2/MC-1 will ignore the
command and transmit a DC_NAK command with an error code DC_ERR_INVALID_DATA.

7.3.19 Set Main Balance

Commands DC-2/MC-1 to set the system balance to the value in this packet.

7.3.19.1 Command Packet Description

Application Header:
Command

DC_CMD_SET_SYS_BALANCE

0x22

Data Count

1

0x01

Application Data:
Data[0]

Value

nn

7.3.19.2 Data Description

Value:

Data Type:

Unsigned 8 bit integer.

Maximum Value:

32

Conversion:

0 = Left
32 = Right

7.3.19.3 DC-2/MC-1 Response

The DC-2/MC-1 will assign the value from the packet to the system balance.

7.3.19.4 Data Validation