Data validation, Set front/back balance, Packet description – Lexicon DC-2 User Manual

Page 26: Data description, Dc-2/mc-1 response, Set active effect by id, Command packet description

Advertising
background image

Lexicon, Inc.
DC-2/MC-1 Serial Communications Protocol

Printed on: 10/19/00

26 of 44

If a value is passed that exceeds the maximum value of that parameter the DC-2/MC-1 will ignore the
command and transmit a DC_NAK command with an error code DC_INVALID_DATA.

7.3.20 Set Front/Back Balance

Commands DC-2/MC-1 to set the front/back balance to the value in this packet.

7.3.20.1 Packet Description

Application Header:
Command

DC_CMD_SET_FRONT_BACK_BALANCE

0x23

Data Count

1

0x01

Application Data:
Data[0]

Value

nn

7.3.20.2 Data Description

Value:

Data Type:

Unsigned 8 bit integer.

Max:

32

Conversion:

0 = Front
32 = Back

7.3.20.3 DC-2/MC-1 Response

The DC-2/MC-1 will assign the value from the packet to the front/back balance.

7.3.20.4 Data Validation

If a value is passed that exceeds the maximum value of that parameter the DC-2/MC-1 will ignore the
command and transmit a NAK command with an error code DC_ERR_INVALID_DATA.

7.3.21 Set Active Effect by Id

Commands DC-2/MC-1 to set the active effect to the value in this packet.

7.3.21.1 Command Packet Description

Application Header:
Command

DC_CMD_SET_EFFECT

0x24

Data Count

1

0x01

Application Data:
Data[0]

EffectId

nn

7.3.21.2 Data Description

EffectId:

Data Type:

Unsigned 8 bit integer

Max:

Set by the Effect Count in the “Unit Configuration Packet”.

7.3.21.3 DC-2/MC-1 Response

The DC-2/MC-1 will load the desired effect.

7.3.21.4 Data Validation

If a value is passed that exceeds the maximum value of that parameter the DC-2/MC-1 will ignore the
command and transmit a NAK command with an error code DC_ERR_INVALID_DATA.

Advertising