LED Acknowledge Enable:

TRUE

Indicates the DC-2/MC-1 will light the green standby LED to

indicate the DC-2/MC-1 is receiving data on the RS232 serial port, and will light the Red Overload LED to
indicate the Dc-2/MC-1 is transmitting data on the RS232 serial port.

FALSE Indicates the DC-2/MC-1 will not light the green standby or the red

overload LED’s.

7.3.32 Set Communication Configuration

The Set Communication Configuration Command allows the serial port user to setup the various serial
port/ protocol configuration parameters.

7.3.32.1 Command Packet Description

Application Header:
Command

DC_CMD_SET_COM_CONFIG

0x30

Data Count

1 0x01

Application Data:
Data[0]

Configuration Register 0

nn

7.3.32.2 Data Description

Data Word

Bit

Definition

0

0

Acknowledge Enable

0

1

Parameter Change Enable

0

2

LED Acknowledge Enable

Acknowledge Enable:

TRUE

Indicates the DC-2/MC-1 will transmit Acknowledge Notification’s to

the Host.

FALSE Indicates the DC-2/MC-1 will not transmit any positive Acknowledge

Notification messages. The DC-2/MC-1 will always transmit NAK error notification messages.

Parameter Change Enable: TRUE

Indicates the DC-2/MC-1 will transmit any paramter change

Notification as specified in the Parameter Change Notification Message.

FALSE Indicates the DC-2/MC-1 will not transmit parameter change

Notifications.

LED Acknowledge Enable:

TRUE

Indicates the DC-2/MC-1 will light the green standby LED to

indicate the DC-2/MC-1 is receiving data on the RS232 serial port, and will light the Red Overload LED to
indicate the Dc-2/MC-1 is transmitting data on the RS232 serial port.

FALSE Indicates the DC-2/MC-1 will not light the green standby or the red

overload LED’s.

7.3.32.3 DC-2/MC-1 Response

The data values transmitted will be copied over to the registers stored in nonvolatile RAM. The DC-2/MC-
1 will respond with an ACK Packet.

7.3.33 Set Mute

The Set Mute Command message allows the RS232 users to set/clear the DC-2/MC-1 mute state directly.

7.3.33.1 Command Packet Description