15.5 Examples:

The following examples show the byte’s transmitted for the Get Unit Config, Get Effect Definition, and Set Input Name transactions. They are shown as they
should be transmitted from left to right.

15.5.1 Get Unit Configuration

The HOST initiates by sending the GET_UNIT_CONFIG command packet:

SOP

DLL DC

CMD

AppDC

EOP

F1

03

15

00

F2

If the command is received with out error the DC-2/MC-1 responds with the UNIT_CONFIG response packet:

SOP

DLL DC

CMD

App DC

DATA0

DATA1

DATA2

DATA3

DATA4

DATA5

DATA6

DATA7

DATA8

Product

Id

SW

TYPE

SW LVL

SW MJ

REV

SW MN

REV

PTCL

MJ REV

PTCL

MN REV

SYS

PARAM
COUNT

EFFECT

COUNT

F1

1C

80

19

00

03

03

03

01

01

00

BE

25

DATA9

DATA10

DATA11

DATA12

DATA13

DATA14

DATA15

DATA16

DATA17

DATA18

DATA19

DATA20

DATA21

DATA22

DATA23

DATA24

EOP

Time

Stamp

Time

Stamp

Time

Stamp

Time

Stamp

Time

Stamp

Time

Stamp

Time

Stamp

Time

Stamp

Time

Stamp

Time

Stamp

Time

Stamp

Time

Stamp

Time

Stamp

Time

Stamp

Time

Stamp

Time

Stamp

39

38

2F

30

36

2F

32

36

20

30

39

3A

35

39

00

00

F2

9

8

/

0

6

/

2

6

(sp)

0

9

:

5

9

From the response packet we can see that the DC-2/MC-1 is configured as a

Product Id is Lexicon DC-2/MC-1
Software type DTS
Software level of alpha
Software Version 3.01
Protocol Version 1.00
with 190 system parameters
and 37 effects,
and the ROM was built
“98/06/26 09:59”