Lexicon, Inc.
DC-2/MC-1 Serial Communications Protocol

Printed on: 10/19/00

5 of 44

The DC-2/MC-1 uses simple notification, command, response and acknowledgment packets to have
communication transactions with a given HOST. This protocol is designed for point to point
communication between a HOST and DC-2/MC-1. The DC-2/MC-1 Protocol is a 3 layered system. The
DC-2/MC-1 serial protocol allows for the DC-2/MC-1, or the HOST to initiate a communication
transaction. Most transactions are initiated by the HOST. DC-2/MC-1 then responds to the HOST
command with either a response or acknowledgment packet. There are a few asynchronous notifications
that DC-2/MC-1 initiates indicating system changes. Each transaction initiated must wait for a
corresponding response before initiating the next transmission.

The 3 protocol layers are: Physical, Data Link, and Application Layers.

5 Physical Layer

5.1 DB-9 RS232 Connector

Dc-2/MC-1

Typical Host

Ch A

Transmit Data

2

2 Rx Data

Ch A

Receive Data

3

3 Tx Data

Ch A

Ground

5

5 Ground

9 Pin D-Shell
(female) lower
connector

9-Pin D-Shell
(male)

Note: The wiring requirements for a 9 pin to 9 pin serial connection, are a male to female straight through
cable.

5.2 Serial Port Driver

DC-2/MC-1 serial port has been setup to operate as follows:

Operating Mode:

Full Duplex

Baud rate:

19.2K baud

Data Size:

8 bits

Parity:

Odd

Stop Bits:

1

Physical Layer (RS232)