A1323 – Allegro Multimedia A1321 User Manual

Page 6

Advertising
background image

Ratiometric Linear Hall Effect Sensor ICs

for High-Temperature Operation

A1321, A1322,

and

A1323

5

Allegro MicroSystems, Inc.

115 Northeast Cutoff

Worcester, Massachusetts 01615-0036 U.S.A.

1.508.853.5000; www.allegromicro.com

MAGNETIC CHARACTERISTICS

1,2

over operating temperature range, T

A

; V

CC

= 5 V, I

out

= –1 mA; unless otherwise noted

Characteristics

Symbol

Test Condition

Min

Typ

3

Max

Units

4

Sensitivity

5

Sens

A1321; T

A

= 25ºC

4.750

5.000

5.250

mV/G

A1322; T

A

= 25ºC

2.969

3.125

3.281

mV/G

A1323; T

A

= 25ºC

2.375

2.500

2.625

mV/G

Delta V

out(q)

as a func-

tion of temperature

V

out(q)(ΔT)

Defi ned in terms of magnetic fl ux density, B

±10

G

Ratiometry, V

out(q)

V

out(q)(ΔV)

±1.5

%

Ratiometry, Sens

ΔSens

(ΔV)

±1.5

%

Positive Linearity

Lin+

±1.5

%

Negative Linearity

Lin–

±1.5

%

Symmetry

Sym

±1.5

%

UA Package
Delta Sens at T

A

= max

5

ΔSens

(TAmax)

From hot to room temperature

–2.5

7.5

%

Delta Sens at T

A

= min

5

ΔSens

(TAmin)

From cold to room temperature

–6

4

%

Sensitivity Drift

6

Sens

Drift

T

A

= 25°C; after temperature cycling and over time

±2

%

LH Package
Delta Sens at T

A

= max

5

ΔSens

(TAmax)

From hot

to room temperature

–5

5

%

Delta Sens at T

A

= min

5

ΔSens

(TAmin)

From cold to room temperature

–3.5

8.5

%

Sensitivity Drift

6

Sens

Drift

T

A

= 25°C; after temperature cycling and over time

±2

%

1

Additional information on characteristics is provided in the section Characteristics Defi nitions, on the next page.

2

Negative current is defi ned as conventional current coming out of (sourced from) the specifi ed device terminal.

3

Typical data is at T

A

= 25°C, except for ΔSens, and at x.x Sens. Typical data are for initial design estimations only, and assume optimum

manufacturing and application conditions. Performance may vary for individual units, within the specifi ed maximum and minimum limits.
In addition, the typical values vary with gain.

4

10 G = 1 millitesla.

5

After 150ºC pre-bake and factory programming.

6

Sensitivity drift is the amount of recovery with time.

Advertising