Air King 4C523K User Manual

9 inch oscillating fan, Operating instructions & parts manual, Ensamblaje

Advertising
background image

4

MODELO 4C523K/9154K

2084020A

Rev. F 9/00

11

22

14-

ENSAMBLAJE

(Ilustración para Ensamble - Pagina 1)

1. Alinea la REJILLA TRASERA con el pasador localizado en la TAPA

DE PLASTICO DEL MOTOR. Dejando los dos agujeros del centro asi
abajo.

2. Asiente la REJILLA y sujetela con la TUERCA DE PLÁSTICO.

3. Para evitar lastimar el HELICE, instalela empujando firmemente en el

centro hacia el EJE del MOTOR.

4. Coloque el GANCHO en la REJILLA DELANTERA sobre el alambre

central superior en la REJILLA TRASERA.

5. Torciendo suavemente quitar del sujetador los GANCHOS de la

REJILLA y colocarlos uniformemente alrededor del ventilador. Fijar
los GANCHOS en la REJILLA. Hacer que la cola del gancho agarre un
alambre redondo de la REJILLA TRASERA. Hacer que el cuerpo del
gancho agarre los bordes planos de ambas rejillas.

(Figura a y b

pagina 1)

OPERACIÓN

1. VELOCIDAD: Las velocidades se controlan mediante el conjuntor

rotatorio localizado en la base del ventilador.

2. OSCILACIÓN: Para hacer oscilar el ventilador, oprima el botón que se

encuentra sobre la cubierta del motor. Para que el ventilador deje de
oscilar, tire del botón hacia afuera.

3. AJUSTE DEL ÁNGULO: Se puede cambiar el ángulo del conjunto

superior del ventilador, aflojando primero el tornillo de elevación. Coloque
el conjunto superior en el ángulo deseado y fíjelo en posición volviendo
a apretar el tornillo de elevación.

LISTA DE REPUESTOS

Ref. No. de Parte

Descripción

Cant.

a) Jalé el boton de oscilacion asi

arriba para desenganchar el
mecanismo de oscilacion.

b) Usé un objecto como un mango

de un destornillador y
gentilmente pegé un golpecito
a la parte delantera de la helice.
No golpear el eje de la helice
asi adentro del motor.

c) Delé vuelta a la helice con la

mano. Si la helice no davuelta
libremente, sigá el paso
posterior hasta que la helice
gire libre.

PRECAUCION: De ninguna
manera prenda su ventilador sin
las revillas y asegurese que
ambas esten bien aseguradas.

TAP
HUB

SPIN

UP

1

2

3

a

b

c

GIRAR

ARRIBA

Centro

EJE

GOLPEAR

LIGERAMENTE

EJE

SPECIFICATIONS

Motor ................................................ 120V, 60 Hz
Blade diameter ................................ 9" (22.9 cm)
Speeds ............................................. 2
Control ............................................. Rotary Switch
Air flow distribution .......................... 90

°

Approvals ......................................... UL Listed. Close mesh fan

guard meets OSHA requirements.

R

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.

PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH

INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

DESCRIPTION

The AirKing 9" (22.9 cm) oscillating fan features whisper-quiet perfor-
mance with a 3-paddle fan blade. The fan has a permanently lubricated
motor with a 6 ft (1.8 m) 18/3 cord set.

1

2084020A

9 INCH OSCILLATING FAN

MODEL 4C523K/9154K

BLADE

MOTOR

PLASTIC
NUT

REAR GRILL

FRONT
GRILL

GRILL CLIP

HOLDER

PLASTIC GRILL

CLIPS

.

HOOK

OSCILLATION CONTROL

ELEVATION
SCREW

SWITCH KNOB

a.

b.

OPERATING INSTRUCTIONS & PARTS MANUAL

MODEL

4C523K/9154K

SPEED

HIGH

LOW

CFM

1205

906

M

3

/s

.57

.43

RPM

2175

1644

Amps

.55

.32

Watts

32

22

dB A

41

34

GENERAL SAFETY INFORMATION

1. Make certain that the power source conforms to the electrical require-

ments of the fan.

2. The power cord is equipped with a three-prong grounded plug that must

be inserted into a matching receptacle. Under no circumstances must
the grounding prong be cut off the plug. Where a two-prong wall
receptacle is encountered, it must be replaced with a properly grounded
three-prong receptacle installed in accordance with the National Elec-
trical Code (NEC) and all applicable local codes and ordinances. This
work must be done only by a qualified electrician, using copper wire only.

WARNING: USE OF A THREE-PRONG TO TWO-PRONG ADAPTER IS
NOT RECOMMENDED. IMPROPER CONNECTION MAY CREATE
THE RISK OF ELECTROCUTION. USE OF SUCH ADAPTERS IS NOT
PERMITTED IN CANADA.

3. Where possible, avoid the use of extension cords. If they must be used,

minimize the risk of overheating by ensuring that they are UL listed and
of the proper gauge and length. Never use a single extension cord to
operate more than one fan.

4. Do not insert fingers or foreign objects into the fan. Do not block or

tamper with the fan in any manner while it is in operation. Do not touch
the fan while in operation or just after it has been turned off, as some
parts may be hot enough to cause injury.

5. Unplug power cord before installing or servicing the fan.

WARNING: DO NOT DEPEND UPON THE ON-OFF SWITCH AS THE
SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR
SERVICING THE FAN. ALWAYS UNPLUG THE POWER CORD.

6. This fan is intended for general use ONLY. It must NOT be used in

potentially dangerous locations such as flammable, explosive, chemi-
cal-laden or wet atmospheres.

WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL
DEVICE.

7. Be sure fan is on a stable surface when operating, to avoid chance of it

overturning.

8. DO NOT use fan in a window. Rain may create an electrical hazard.

9. Completely reassemble fan, according to instructions before reconnect-

ing to power supply.

MAINTENANCE

WARNING: ALWAYS UNPLUG THE CORD BEFORE SERVICING.

CLEANING

: Use a soft cloth and a mild soap solution such as liquid dish

washing detergent.
CAUTION: Do not use gasoline, benzine, thinner, harsh cleaners,
etc. which will damage the fan.
Dry all parts with a soft cloth completely before reconnecting to power
supply.

STORAGE

: When not in use, keep unit in a clean dry place.

MOTOR IS PERMANENTLY LUBRICATED.

Rev. F 9/00

1

2050009AW Cordón Eléctrico

1

2

2096045

Rejilla Delantera

1

3

2010004

Hélice

1

4

2010350

Tuerca de Plástico

1

5

2096050

Rejilla Trasera

1

6

2030056G

Motor

1

7

2010619

Cubierta del Motor

1

8

2010119

Botón de Oscilación

1

10 2010279

Enlace

1

11 2090068

Tornillo #6 x 1/2" LH/H.W.H.

1

12 2010260

Cuello

1

13 2091133

Tuerca Hexagonal de 1/4 x 20

1

14 2090529

Tuerca Para Alambre

1

15 2090199

Tornillo Phillips de 1/4 - 20 x 1"
PPH Tornillo de Elevación

1

16 2010104

Botón del Interruptor

1

17 2065412

Ornamento de la Base

1

18 2010524

Base

1

19 2057065

Conjuntor Rotatorio

1

20 2010281

Placa Inferior

1

21 2010403A

Pata de Caucho (4 utilizadas)

4

22 2090038

Tornillo Phillips de Cabeza
Reforzada #8 x 9/16 PPH

2

23 2010354

Sujetador de Rejilla

5

24 2066506G

Accesorio del Botón del
Interruptor

1

25 2010241A

Ornamento del Rejilla

1

26 2070024G

Ojo de Buey (AirKing)

1

27 2090073

Tornillo #6 x 1/2" AB

1

27

Advertising
This manual is related to the following products: