background image

Electric Fryer Operation & Care Manual • 15

O P E R A T I O N

NOTE:

Perform an initial Boil-Out to clean and

sanitize the fryer station before operating.

1.

Service is to be performed by an authorized

Alto-Shaam service agent.

2.

Ensure all local electrical codes, fire codes, and all

other requirements such as hood installation have

been met in the process of installation.

NOTE:

Because each fryer station is controlled

separately, the following procedures must

be followed for every component fryer in

multiple-station units.

3.

Open front access door and ensure drain valve is

in the “CLOSED” position. The handle should be

rotated clockwise until it stops.

4.

Fill frypot with frying compound as indicated.

(

see

illustration

on

the

oil

/

shortening

requirements

page

)

5.

The Master Power Switch is located behind the front

access door. Turn Master Power Switch “ON.”

6.

Press the ELEMENT HI-LIMIT RESET button.

7.

The

LED

display on the control panel will indicate

“-AS-”

, the software version, and then “C ”.

8.

When the fryer has reached 135°F, the melt cycle is

complete and the LED display on the control panel

will indicate “HEAt”.

9.

When the fryer displays the set-point temperature,

product can be fried.

10.

More detailed operating guidelines along with

information on programming are located within this

manual.

11.

To shut the fryer station down, turn the Master Power

Switch located behind the front access door to the

“OFF”

position.

NOTE:

for

your

protection

The fryer station is

furnished with a hi-limit safety shutoff that will

disengage the control if the frying compound

temperature in the frypot would ever exceed

415°F (213°C). The LED will display “Hi”, the

heat will shut off, the timer will be cancelled,

and a constant alarm will sound. In this event,

allow the frying compound temperature to drop

below 415°F (213°C). Open the front access door

and press the OIL HI-LIMIT RESET button for

a period of 3-seconds to restart the control.