Installation: temperature adjustment, Acorn controls – Acorn ST70 VALVE User Manual

Page 4

Advertising
background image

Manual #7802-112-001

Page 4 of 5

1. Locate mixing valve in a suitable place

accessible for servicing and adjusting. Valve
should be as close as possible to point of use.

2. Thoroughly flush supplies.
3. Connect Hot and Cold supplies to mixing valve

inlets and outlet to faucet(s). ST70-12: Valve
connections are 1/2” NPT, for supply lines
by others. ST70-38: Valve connections are
3/8” compression, Detail A. Supply tubing by
others.

4. Turn on supplies and inspect for leaks. Tighten

connections if leak(s) are detected.

5. Turn on faucet and allow to run until water

temperature stabilizes. Measure water
temperature. If water is not at desired
temperature adjust as needed, (refer to
adjustment section below). Maximum
recommended outlet temperature is 105° F
(41° C).

INSTALLATION:

TEMPERATURE ADJUSTMENT:

1. Loosen locknut. Detail B
2. Turn faucet on so water temperature can

stabilize.

3. Using 1/8” allen wrench turn adjustment stem

counter-clockwise for hotter or clockwise for
colder outlet temperature. Detail C

4. Tighten locknut to prevent any unauthorized

or accidental temperature adjustment.

5. Re-check temperature.

Acorn Controls

Division of Acorn Engineering Company

®

, A member of Morris Group International

INSTALLER PROVIDED

SUPPLY ANGLE STOPS

INSTALLER PROVIDED
FLEXIBLE HOSES

1/8" ALLEN WRENCH

TYPICAL INSTALLATION

ADJUSTMENT

STEM

COMPRESSION

NUT

FERRULE

DETAIL A

SUPPLY TUBING
BY OTHERS

5/8" WRENCH

LOCKNUT

DETAIL B

DETAIL C

Date: 04/01/14

ST70 Installation & Operation Manual