AFX CAF12213QENSN User Manual

Carlise flush series, Flushmount fixture, Safety precautions

Advertising
background image

Carlise Flush Series

Flushmount Fixture

Models: CAF12/14/24

8060360 r0

www.afxlighting.com

1 of 1

Limited Factory Warranty
AFX Lighting, Inc. warrants this fixture is free from defects in materials and workmanship when installed and used under normal operating conditions
for a period of 3 years from date of purchase. This warranty covers all component parts and extends only to replacement of defective fixture or
components; it does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit.

Figure 3

Figure 2

Safety Precautions

Read all safety precautions and installation instructions carefully before
installing or servicing this fixture. Failure to comply with these
instructions could result in potentially fatal electric shock and/or
property damage.

It is recommended that a qualified electrician perform all wiring. This
fixture must be wired in accordance with all national and local
electrical codes.

Do not handle any energized fixture or attempt to energize any fixture
with wet hands or while standing on a wet or damp surface or in water.


Make sure that the power source conforms to the requirements of the
fixture (see labels on fixture housing).

To reduce the risk of electrical shock, and to assure proper operation,
this fixture must be adequately grounded. To accomplish proper
grounding, there must be a separate ground wire (green) contact
between this fixture and the ground connection of your main power
supply panel.

This fixture is intended to be used for general indoor lighting in damp
locations.

ASSEMBLY INSTRUCTIONS

1. Preparing for installation
A. Disconnect electrical power at fuse or circuit breaker box

before installing or servicing any part of this fixture.

B. Carefully remove the fixture from the carton, and check

that all parts are included, as shown in Figure 1.

2. Wiring – all wiring must take place inside junction box
Caution:
Make sure power is off at fuse or circuit breaker

box. Check power wires for damage or scrapes. If power
supply wires are within three inches of the ballast power
supply, use wire suitable for at least 90C (194F). Note:
Most dwellings built before 1985 have supply wire rated to
60C. Consult a qualified electrician before installing.

A. Connect the power source ground wire to the green or bare

copper wire from the fixture assembly.

B. Using wire nuts, connect white supply wire to white fixture lead. Connect black supply wire to

black fixture lead. Do not mix wires. Pull on each wire lead to make sure connections are
secure. Make certain no bare wires are exposed outside of wire connectors. Note: fixtures
with universal voltage power supplies are pre-wired with a disconnect. Refer to the included
guide for using the disconnect.

C. Tuck all connections neatly into junction box.

3. Mounting
A. Install fixture by securing the ceiling pan (1) to the ceiling using the semi-circular slots and/or

outer keyhole slots (Figure 2). Note: over-tightening can warp/bend the ceiling pan.

B. If required, install lamps (6). For CFQ lamps: push lamp into lamp holder until it snaps in

place. For GU24 lamps: insert lamp into lamp holder and turn it
clockwise until it snaps in place.

C. Place diffuser (2) over ceiling pan. Install trim ring (4) and brackets (3)

using thumb nuts (5). Note – to enable single-person mounting, install
trim ring with one bracket and thumb nut, then insert diffuser and install
remaining brackets (Figure 3).

4. Restore power at fuse or circuit breaker box

Figure 1

Model CAF14218QMVSN Shown

Advertising
This manual is related to the following products: