AFX CVF32232C927ENSN User Manual

Csv series, Surface mounted fluorescent fixture, Safety precautions

Advertising
background image

CSV Series

Surface Mounted Fluorescent Fixture

Model 3232

Page 1 of 1

8060069 rev.5

Safety Precautions

Read all safety precautions and installation instructions carefully
before installing or servicing this fixture. Failure to comply with
these instructions could result in potentially fatal electric shock
and/or property damage.

It is recommended that all wiring be performed by a qualified
electrician. This fixture must be wired in accordance with all national
and local electrical codes.

Do not handle any energized fixture or attempt to energize any
fixture with wet hands or while standing on a wet or damp surface or
in water.

Make sure that the power source conforms to the requirements of the
fixture. (See labels on fixture housing).

To reduce the risk of electrical shock, and to assure proper operation,
this fixture must be adequately grounded. To accomplish proper
grounding, there must be a separate ground wire (green) or bare metal
contact (metal conduit) between this fixture and the ground
connection of your main power supply panel. The green ground
screw location is clearly marked on the fixture housing.

This fixture is intended to be used for general indoor lighting in dry
or damp locations only.

Assembly Instructions

1.

Preparing for installation

A. Disconnect electrical power before installing or servicing any part of this

fixture.

B. Remove fixture from cartoning; remove trim band (2) and diffuser (3) by

removing the 4 thumb screws (1).

2.

Wiring.

All wiring must take place inside junction box.

Caution

: Make sure

power is off at fuse or circuit breaker box. Check power wires for damage or
scrapes. If power supply wires are within three inches of ballast use wire suitable
for at least 90C (194F). Note: Most dwellings built before 1985 have supply
wire rated to 60C. Consult a qualified electrician before installing.

A. This unit will not operate properly unless connected to a “grounded”

electrical circuit. Electrical shock, over heating, low or no light output, and
shortened lamp life can result if proper grounding is not done. Securely
attach green (or green and yellow) wire to ground supply wire.

B. Using wire connectors (provided), connect white supply wire to white

ballast lead. Connect black hot supply wire to black ballast lead. Do not mix
wires.
Pull on each wire lead to make sure connections are secure. Make
certain no bare wires are exposed outside of wire connectors.

3.

Mounting

A. Junction Box mounting; Attach fixture channel (7) directly to Junction box through eyelet holes with two #8 –32 x 1” screws.

(Provided). Additional holes are supplied in channel for fixture mounting support.

4.

Lamping

A. Install lamps (4) around three clips (5) and connect sockets to prongs on lamps

5.

Diffuser mounting

A. Slide the diffuser (3) and trim band (2) over the channel (7) and secure with 4 thumb screws (1) onto threaded offsets (6)

6.

Power to the fixture can now be restored

Limited Factory Warranty
AFX Lighting, Inc. hereby warranty that this fixture is free from defects in materials and workmanship when installed and used under normal operating
conditions for a period of 3 years from date of purchase. This warranty covers all component parts and extends only to replacement of defective fixture
or components; it does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit. This product uses an ENERGY
STAR approved ballast. In the event that ballast replacement is required, please contact a qualified electrician.

Advertising
This manual is related to the following products: