AFX TPDW70050LBK User Manual

Outdoor flood light, Led flood light, Safety precautions

Advertising
background image

Outdoor Flood Light

LED Flood Light

Model: 326912 & 326930 (TPDW70050LBK/TPDW110050LBK)

120VAC / 60Hz

8060665 R5

1 of 1

Limited Factory Warranty
AFX Lighting, Inc. warrants this fixture is free from defects in materials and workmanship when installed and used under normal operating conditions for a
period of 3 years from date of purchase. This warranty covers all component parts and extends only to replacement of defective fixture or components; it does
not cover failure due to improper installation, misuse, mishandling or damage incurred in transit.

Safety Precautions

Read all safety precautions and installation instructions carefully
before installing or servicing this fixture. Failure to comply with these
instructions could result in potentially fatal electric shock and/or
property damage.

It is recommended that a qualified electrician perform all wiring. This
fixture must be wired in accordance with all national and local
electrical codes.

Do not handle any energized fixture or attempt to energize any fixture
with wet hands or while standing on a wet or damp surface or in water.


This fixture is designed for use in a 110-120VAC, 60Hz fused circuit.
Do not use on a dimming circuit.

To reduce the risk of electrical shock, and to assure proper operation,
this fixture must be adequately grounded. To accomplish proper
grounding, there must be a separate ground wire (green) contact
between this fixture and the ground connection of your main power
supply panel.

This fixture is intended to be used for general outdoor lighting in wet
locations.

ASSEMBLY INSTRUCTIONS

1. Preparing for installation

A. Disconnect electrical power at fuse or circuit breaker box before installing or servicing any part of
this fixture.
B. Carefully remove the fixture from the carton.
2. Wiring-all wiring must take place inside junction box (not included)
Caution:
Make sure power is off at fuse or circuit breaker box. Check power wires for damage or
scrapes. If power supply wires are within three inches of the ballast power supply, use wire suitable for at
least 90C (194F). Note: Most dwellings built before 1985 have supply wire rated to 60C. Consult a
Microsoft Word qualified electrician before
installing.
A. Secure fixture arm (3) on the threaded cover
(4) (not supplied) with locknut (5) (supplied).
B. Make all wire connections to appropriate
wire. Secure with wire nuts (included).
C. Connect the green wire from the fixture to the
power source green wire.
D. The black wire from the fixture is connected
to the black wire from power source.
E. The white wire from the fixture is connected
to the white (neutral) wire from power source.
F. Tuck all connections neatly into junction box.
G. Secure threaded cover (4) on the junction box
with two screws (not supplied).
5. Positioning Fixture with the Swivel/Arm
Assembly
A. Loosen the nut (2) on the swivel arm
assembly base. Adjust the correct fixture aiming
angle position by rotating it upward or
downward. Tighten the nut (2).
6. Restore power at fuse or circuit breaker box.