AFX CMB332ESE8 User Manual

Fluorescent vanity fixture, Safety precautions, Assembly instructions

Advertising
background image

CMB

Fluorescent Vanity Fixture

Models 325/332

Safety Precautions

Read all safety precautions and installation instructions carefully
before installing or servicing this fixture. Failure to comply with
these instructions could result in potentially fatal electric shock
and/or property damage.

It is recommended that a qualified electrician perform all wiring. This
fixture must be wired in accordance with all national and local
electrical codes.

Do not handle any energized fixture or attempt to energize any
fixture with wet hands or while standing on a wet or damp surface or
in water.

Make sure that the power source conforms to the requirements of the
fixture (see labels on the fixture housing). Do not use on a dimming
circuit.

To reduce the risk of electrical shock, and to assure proper operation,
this fixture must be adequately grounded. To accomplish proper
grounding, there must be a separate ground wire (green) or bare metal
contact (metal conduit) between this fixture and the ground
connection of your main power supply panel. The green ground
screw location is clearly marked on the fixture housing.

This fixture is intended to be used for general indoor lighting in dry
or damp locations only.

Assembly Instructions

1. Preparing for installation

A.

Disconnect electrical power before installing or
servicing any part of this fixture.

B.

Remove divider (5), screws (4), wire way cover
(5) and screws (6).

C.

Remove the appropriate knockout(s) for power
supply entry (9).

2. Fixture mounting.

A.

To locate, hold channel (8) up to the wall with
power supply knockout located over entryway for
power supply wires. Mark the locations of the
mounting holes on the wall. Take the channel
down and punch a small hole into the wall at each
location using a nail or an awl to see if there is a
wood joist. If there is a joist use a suitable wood
screw (not included) to mount the channel (8).
Where there is no joist to screw into use a toggle bolt (not included) of suitable length to mount channel securely to the wall. Proceed to
step B before final mounting.

B.

Feed the black and white supply wires, and the green ground wire into the fixture through the open knockout hole. At this time you can
finish mounting the channel (5) to the wall.

3. Wiring.

Caution: Make sure power is off at fuse or circuit breaker box. Check power wires for damage or scrapes. If power supply wires are within
three inches of ballast use wire suitable for at least 90C (194F). Note: Most dwellings built before 1985 have supply wire rated to 60C. Consult
a qualified electrician before installing.

A.

This unit will not operate properly unless connected to a “grounded” electrical circuit. Electrical shock, over heating, low or no light
output, and shortened lamp life can result if proper grounding is not done. Securely attach green (or green and yellow) wire to provided
green ground screw.

B.

Using wire connectors (provided), connect white supply wire to white ballast lead(s) and night light lead. Connect black hot supply wire to
black leads from switches. Do not mix wires. Pull on each wire to make sure connections are secure. Make certain no bare wires are
exposed outside of wire connectors. Note – for models with luminaire disconnect pre-wired to ballast, reference the included
instruction insert.

C.

Install wire way cover (7) and divider (5).

D.

Install appropriate lamp(s) (3) (not included) by inserting lamp pins into lamp holder. Rotate into place to seat lamp for proper connection.

4. Diffuser mounting.

A.

Position the 1” diameter acrylic spacers (not pictured) over the frame mounting holes at each end of the fixture channel (8).

B.

Position frame (1) over the mounted fixture channel (8), align holes and secure with frame mounting screws (2) & decorative washers.

Power to the fixture can now be restored.

Limited Factory Warranty
American Fluorescent Corporation hereby warranty that this fixture is free from defects in materials and workmanship when installed and used under normal operating
conditions for a period of 2 years from date of purchase. This warranty covers all component parts and extends only to replacement of defective fixture or components;
it does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit.

Page 1 of 1

8060099-Rev3

Advertising
This manual is related to the following products: