ADCP-75-169 • Issue 1 • June 2004

Page 16
© 2004, ADC Telecommunications, Inc.

Figure 14. Fiber Optic Cable Connections To Host Unit

6. Route the patch cords from the HU to the fiber distribution panel.

7. At the fiber distribution panel, identify the OSP cable optical fiber terminations that

correspond to the forward, reverse, and diversity reverse (if supported) paths.

8. Remove the dust caps from the OSP cable optical fiber adapters and from the patch cord

connectors.

9. Clean each patch cord connector (follow patch cord supplier’s recommendations) and then

mate the connector with the appropriate OSP cable adapter.

10. Store any excess patch cord slack at the fiber distribution panel.

4.8.2

Optical Connections With WDM System

Use the following procedure to connect the optical fibers when a WDM module is installed with
the HU:

1. Obtain a patch cord that is of sufficient length to reach from the WDM module to the fiber

distribution panel.

2. Remove the dust cap from the optical port (Port 1) on the WDM module and from the

patch cord connector that will be connected to the WDM module.

Note: The HU optical adapters are angled to the left. Therefore, always route patch cords
to the HU from the left side of the rack. Routing patch cords to the HU from the right may
exceed the bend radius limitations for the optical fiber.

19721-A

PORT 1

FORWARD PATH

PORT 2

REVERSE PATH

PORT 3

DIVERSITY