Wall Sconce

Fluorescent Wall Fixture

Model: RDS226WHPLT

120VAC / 60Hz

8060671 R0

1 of 1

Limited Factory Warranty

AFX Lighting, Inc. warrants this fixture is free from defects in materials and workmanship when installed and used under normal operating
conditions for a period of 2 years from date of purchase. This warranty covers all component parts and extends only to replacement of defective
fixture or components; it does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit.

Safety Precautions

Read all safety precautions and installation instructions carefully
before installing or servicing this fixture. Failure to comply with these
instructions could result in potentially fatal electric shock and/or
property damage.

It is recommended that a qualified electrician perform all wiring. This
fixture must be wired in accordance with all national and local
electrical codes.

Do not handle any energized fixture or attempt to energize any fixture
with wet hands or while standing on a wet or damp surface or in water.


This fixture is designed for use in a 110-120VAC, 60Hz fused circuit.
Do not use on a dimming circuit.

To reduce the risk of electrical shock, and to assure proper operation,
this fixture must be adequately grounded. To accomplish proper
grounding, there must be a separate ground wire (green) contact
between this fixture and the ground connection of your main power
supply panel.

This fixture is intended to be used for general indoor lighting in dry
locations.

ASSEMBLY INSTRUCTIONS

1. Preparing for installation
A. Disconnect electrical power at fuse or circuit breaker box before
installing or servicing any part of this fixture.
B. Carefully remove the fixture from the carton.

2. Wiring – all wiring must take place inside junction box (not
included)
Caution:
Make sure power is off at fuse or circuit breaker box. Check
power wires for damage or scrapes. If power supply wires are within three
inches of the ballast power supply, use wire suitable for at least 90C
(194F).
Note: Most dwellings built before 1985 have supply wire rated to 60C.
Consult a qualified electrician before installing.
A. Marked four fixture mounting holes location by using backpanel as a

template (dimensions between holes 4 5/16” x 7 5/8”).

B. Drill four ¼” dia holes 1”deep for plug anchors (supplied). Install four

plug anchors (1) into the wall.

C. Pull the supply wires and the ground wire out from the outlet box (not

supplied).

C. Make all wire connections to appropriate wire. Secure with wire nuts

(included).

D. Connect the green wire from the fixture to the power source green wire.
E. The black wire from the fixture is connected to the black wire from

power source.

F. The white wire from the fixture is connected to the white (neutral) wire

from power source.

G. Tuck all connections neatly into junction box.

3. Mounting
A. Position fixture (3) on the wall by aligning the mounting holes.
B. Install the fixture (3) by securing it with four (2) screws (supplied).

4. Installing Lamps – Insert lamps (4) into lamp holder (5) and press upwards until lamp snaps in place.

5. Lens – Slide lens (6) into the frame.

6. Restore power at fuse or circuit breaker box.