AFX EXL120WH User Manual

Exl series, Assembly instructions, Line voltage xenon undercabinet fixture

Advertising
background image

EXL SERIES

Line Voltage Xenon Undercabinet Fixture

Models 120, 220, 320, & 420

Interconnectable / Cord or Direct Wire

Page 1 of 2

8060525 R7

Safety Precautions

Read all safety precautions and installation instructions carefully

before installing or servicing this fixture. Failure to comply with

these instructions could result in potentially fatal electric shock

and/or property damage.

It is recommended that a qualified electrician perform all wiring. This

fixture must be wired in accordance with all national and local

electrical codes.

Do not handle an energized fixture or attempt to energize any fixture

with wet hands or while standing on a wet or damp surface or in

water.

Make sure that the power source conforms to the requirements of the

fixture. (See labels on fixture housing).

To reduce the risk of electrical shock, and to assure proper operation,

this fixture must be adequately grounded.

Lighted lamp is HOT!

Bulb gets HOT quickly! Do not touch hot lens or enclosure.

Do not touch bare lamp with your bare skin. Oils from

your skin may damage the lamp when it heats up.

12-inch minimum spacing distance from glass required

for all objects located under fixture.

FOR Model No: EXL Series:

Do not interconnect more than 560 watts

Example: 560 watts (28 lamps x 20w)

Use only a 120V/20W or smaller Xenon bulb (bi-pin Base Only).

This fixture is to be used for general indoor lighting in dry locations

only.

Dimming: This unit can be dimmed with a standard incandescent

wall dimmer.

Assembly Instructions

1. Preparation for Installation

A. Disconnect electrical power before installing or servicing any part of this

fixture.

B. Place fixture on a clean flat surface with lens (1) towards you.

C. Remove glass lens by lightly pressing down on both ends while sliding it

directly away from the fixture.

D. If lamps are not installed and packed separately, carefully put aside for later

use. (DO NOT TOUCH LAMP glass with bare hands, oils from your skin

may damage lamp when it heats up.)

E. Determine input power method (Hardwire, Cord or Link) below and follow

corresponding directions.

2.

Cord to Outlet Installation

(Skip this step if using Hardwire or Link to Fixture Installation)

A. Fixture must be mounted within 5’ of an outlet. Locate the 5’ power cord included in the box.

B. Connect Cord to fixture by snapping the quick connect end of the cord to the corresponding connector in the end of the

fixture marked “IN”. The cord will only connect to the “IN” connector so make sure you have the right connector identified.

Do not force the connection, it should snap in easily.

C. Follow the directions for Mounting and Lamping below.

D. Once Mounting and Lamping are completed, plug the cord into the outlet.

3.

Hardwire Installation Preparation

(Skip this step if using Cord to Outlet or Link to Fixture Installation to Power Unit)

A. Discard Cord if Hardwire Installation is used.

B. Open cover by squeezing to disengage it from the

retaining tabs of the housing. Rotate it 90º.

C. Remove appropriate 7/8” diameter knockout for supply

wiring entry.

D.

Determine appropriate connector:

i)

NM-Romex - A non-metallic push-on connector is

included for use.

ii) Flexible conduit (BX)– A push-on connector

(shown) is included for use.

E. Insert BX cable (not included) or Romex (not included)

through appropriate connector. Feed appropriate supply

wires (1 black wire, 1 white wire and a ground wire)

through open 7/8” hole in the housing and push connector into hole until it snaps in place.

F. Follow the directions below for Mounting then proceed to Hardwire Installation Completion.

Advertising
This manual is related to the following products: