AFX CRV221RBMV User Manual

Series, Fluorescent vanity fixture, Safety precautions

Advertising
background image

CRV

Series

Fluorescent Vanity Fixture

Model 221


Page 1 of 1

8060452 rev.6

Safety Precautions

Read all safety precautions and installation instructions carefully
before installing or servicing this fixture. Failure to comply with
these instructions could result in potentially fatal electric shock
and/or property damage.

It is recommended that a qualified electrician perform all wiring. This
fixture must be wired in accordance with all national and local
electrical codes.

Do not handle any energized fixture or attempt to energize any
fixture with wet hands or while standing on a wet or damp surface or
in water.

This fixture is designed for use in a 120-277VAC, 60Hz fused circuit.
Do not use on a dimming circuit.

To reduce the risk of electrical shock, and to assure proper operation,
this fixture must be adequately grounded. To accomplish proper
grounding, there must be a separate ground wire (green) or bare metal
contact (metal conduit) between this fixture and the ground
connection of your main power supply panel. The green ground
screw location is clearly marked on the fixture housing.

This fixture is intended for use for general indoor lighting in dry or
damp locations only.

Assembly Instructions

1.

Preparing for installation

A. Disconnect electrical power before installing or

servicing any part of this fixture.

B. After carefully unpacking the fixture, remove the ballast

cover (5) by removing the 2 thumbnuts (9) and pulling
cover off mounting pan.

C. Install junction box cover plate (4) to junction box with

#8 screws (not provided).

D. Line up wire hole of mount pan with your junction box

(not provided). Use a level to be sure fixture is straight.
Mark locations of mounting location with a pencil. Insert
1” wood screws (included) into marked holes leaving
them about 1/8” away from wall. Where there is no joist
for mounting use toggle bolts (not included) of suitable
length to mount pan securely to wall.

E. Pull lead wires through wire hole, line up mounting slots

with screws and slide fixture in place. Tightening mount screws.

2.

Wiring.

All wiring must take place inside junction box.

Caution: Make sure power is off at fuse or circuit breaker box. Check power wires for damage or scrapes. If power supply wires are
within three inches of ballast use wire suitable for at least 90C (194F). Note: Most dwellings built before 1985 have supply wire rated
to 60C. Consult a qualified electrician before installing.

A. This unit will not operate properly unless connected to a “grounded” electrical circuit. Electrical shock, over heating, low or

no light output, and shortened lamp life can result if proper grounding is not done.

B. Using luminaire disconnect (provided), insert white supply wire into the hole across from white ballast lead. Insert black hot

supply wire into hole across from black ballast lead. Do not mix wires. Pull on each wire to make sure connections are
secure. Make certain no bare wires are exposed outside of luminaire disconnect.

C. Replace the ballast cover by lining up the holes with the threaded studs (3) in the channel and thread thumbnuts (9) securely.

3.

Fixture Lamping.

A. This fixture uses 2 – 21 watt T5 linear fluorescent lamps (6 - not provided).
B. Inserting lamp pins into sockets and rotate until lamp snaps into place.

4. Diffuser installation

.

A. Line the holes (7) on diffuser (8) with holes on diffuser mounting bracket and slide diffuser into place. Attach using thumb

screws (1) and adjust diffuser for tight fit to wall. Tighten thumbscrews.

B.

Restore power at fuse or circuit breaker box.

Limited Factory Warranty
American Fluorescent Corporation hereby warranty that this fixture is free from defects in materials and workmanship when installed and used under normal operating
conditions for a period of 2 years from date of purchase. This warranty covers all component parts and extends only to replacement of defective fixture or components;
it does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit.

Advertising