AFX CZV326SNSCT-WHWH User Manual

Czv series, Fluorescent vanity fixtures, Safety precautions

Advertising
background image

CZV Series

Fluorescent Vanity Fixtures

Models 218, 318, 418, 226, 326, 426

Page 1 of 1

8060721 Rev.0

Safety Precautions

Read all safety precautions and installation instructions carefully
before installing or servicing this fixture. Failure to comply with
these instructions could result in potentially fatal electric shock
and/or property damage.

It is recommended that a qualified electrician perform all wiring. This
fixture must be wired in accordance with all national and local
electrical codes.

Do not handle any energized fixture or attempt to energize any
fixture with wet hands or while standing on a wet or damp surface or
in water.

Make sure that the power source conforms to the requirements of the
fixture. (See labels on fixture housing). Do not use on a dimming
circuit.

To reduce the risk of electrical shock, and to assure proper operation,
this fixture must be adequately grounded. To accomplish proper
grounding, there must be a separate ground wire (green) or bare metal
contact (metal conduit) between this fixture and the ground
connection of your main power supply panel. The green ground
screw location is clearly marked on the fixture housing.

This fixture is intended to be used for general indoor lighting in dry
and damp locations.

Assembly Instructions

1.

Preparing for installation

A. Disconnect electrical power before installing or servicing

any part of this fixture.

B. Carefully remove fixture from packaging and separate.
C. Secure the wall mounting plate (1) to wall using wood

screws (not shown) or anchors (provided) where there is
no stud using the provided key holes (8).

2.

Wiring.

All wiring must take place inside junction box.

Caution: Make sure power is off at fuse or circuit breaker box.
Check power wires for damage or scrapes. If power supply wires
are within three inches of ballast use wire suitable for at least 90C
(194F). Note: Most dwellings built before 1985 have supply wire
rated to 60C. Consult a qualified electrician before installing.

A. This unit will not operate properly unless connected to a

“grounded” electrical circuit. Electrical shock, over-
heating, low or no light output, and shortened lamp life can result if proper grounding is not done. Securely attach green (or
green and yellow) wire to green ground screw on gem bar with provided hardware.

B. Using wire connectors, connect white supply wire to white fixture lead. Connect black hot supply wire to black fixture lead.

Do not mix wires. Pull on each wire lead to make sure connections are secure. Make certain no bare wires are exposed
outside of wire connectors.

3.

Fixture mounting.

A. Align the back plate (10) holes and its mounting holes (2) over wall mounting screws (7) and secure into place with thumb

nut (5).

B. 4-pin CFG Lamp - Install appropriate lamps (6) (not included) by inserting lamp pins into socket base and press until lamp

snaps in place. Repeat until all lamps are installed.

C. GU24 Lamp - Install appropriate lamps (6) (included) by aligning pins and rotating. Repeat until all lamps are installed.

4. Diffuser installation

A. Slide diffuser into back plate (10) and align holes in diffuser (3) with holes in the back plate (9). Gently tighten thumb screws

(4) in back plate holes (9). Repeat until all diffusers (3) are installed.

B. Restore power at fuse or circuit breaker box.



Limited Factory Warranty
AFX Lighting, Inc. hereby warranty that this fixture is free from defects in materials and workmanship when installed and used under normal operating conditions for a
period of 2 years from date of purchase. This warranty covers all component parts and extends only to replacement of defective fixture or components; it does not cover
failure due to improper installation, misuse, mishandling or damage incurred in transit.

Advertising
This manual is related to the following products:
Table of contents