Safety Precautions

Read all safety precautions and installation instructions carefully
before installing or servicing this fixture. Failure to comply with
these instructions could result in potentially fatal electric shock
and/or property damage.

It is recommended that a qualified electrician perform all wiring. This
fixture must be wired in accordance with all national and local
electrical codes.

Do not handle any energized fixture or attempt to energize any
fixture with wet hands or while standing on a wet surface.

This fixture is designed for use in a 110-120VAC, 60Hz fused circuit.
Do not use on a dimming circuit.

To reduce the risk of electrical shock, and to assure proper operation,
this fixture must be adequately grounded. To accomplish proper
grounding, there must be a separate ground wire (green) or bare metal
contact (metal conduit) between this fixture and the ground
connection of your main power supply panel.

This fixture is intended to be used for general outdoor lighting
in wet locations, mounted at least 4’ above ground level.

Assembly Instructions

1.

Preparing for installation.

Note:

A 4-inch junction box will not be completely covered during the mounting

of this fixture.

A. Disconnect electrical power before installing or servicing any part of this

fixture.

B. Remove fixture from carton, place the endcap (6) and diffuser (7) aside.

Separate contents of red hardware bag.

2.

Wiring. All supply wiring connections must take place inside
junction box.

Caution: Make sure power is off at fuse or circuit breaker box. Check power wires
for damage or scrapes. Consult a qualified electrician before installing.

A. This unit will not operate properly unless connected to a “grounded”

electrical circuit. Electrical shock, over heating, low or no light output, and
shortened lamp life can result if proper grounding is not done. Securely
attach green and yellow wire from back of fixture to gem bar (1) gnd.

B. Using wire connectors (provided), connect white supply wire to white

lead(s). Connect black hot supply wire to black lead. Do not mix wires.
Make sure connections are secure and tucked carefully into junction box
(not provided).

3.

Fixture mounting.

A. Install gem bar (1) with #8-32 x 1-1/8” screws (provided) to junction box.

Use the lock nut provided to secure stem (2) at the proper length.

B. Install fixture (3) over stem and secure in place with knob (4). (Note:

adjust length of stem to create secure fit.)

C. Apply a bead of silicone sealant (not supplied) around all 4 edges of back

pan (3) at wall following manufacturer’s instructions.

4. Lamp and Diffuser installation

.

A. Insert the correct (4-pin, 13 watt G24q-1 base) compact fluorescent lamp (not provided) into socket until it snaps into place.
B. Position diffuser (7) inside bottom endcap. Place clear gasket and top endcap (6) on top of backpan, capturing diffuser.

Secure with thumbscrew (5).

C.

Restore power at fuse or circuit breaker box.

NOTE: If the fixture

is provided with a photocell, it is pre-wired from the factory. This unit will not operate until

insufficient ambient light allows the photocell to operate the lamp.

Limited Factory Warranty
American Fluorescent Corporation hereby warranty that this fixture is free from defects in materials and workmanship when installed and used under normal operating
conditions for a period of 2 years from date of purchase. This warranty covers all component parts and extends only to replacement of defective fixture or components;
it does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit.