Chapter 10: Replacing Modules

220

Replacing AT-SBxPWRSYS1 AC and AT-SBxPWRPOE1 Power
Supplies

This section contains the procedure for removing AT-SBxPWRSYS1 AC
and AT-SBxPWRPOE1 Power Supplies from the AT-SBx3106 Chassis.

Note

The illustrations in the following procedure show the removal of an
AT-SBxPWRSYS1 AC Power Supply from slot D. The procedure is
the same for all power supply slots.

Note

Allied Telesis recommends creating a backup copy of the database
file of the chassis with the BACKUP DATABASE FILE command
before removing or replacing a power supply. For instructions, refer
to the Software Reference for SwitchBlade x3100 Series Switches.

To remove an AT-SBxPWRSYS1 AC or AT-SBxPWRPOE1 Power Supply
from the chassis, perform the following procedure:

1. Disconnect the AC power cord for the power supply from the AC

power source and the corresponding AC socket on the back panel of
the chassis. The figure in Figure 152 on page 221 shows the removal
of the power cord from connector D, which corresponds to slot D on
the front panel.