Hot Swapping

There are two methods for installing and removing NSMs: the standard installation
method and the hot swap installation method. The software release running on your
switch or router determines which of these two methods should be used.

If your switch or router is running Software Version 2.2.3 or earlier, follow the
standard method. If your switch or router is running Software Version 2.3.1 or later,
you can use the hot swap method.

To find out which software release your switch or router is running, use the
command:

show system

The following installation procedure describes how to install an NSM using either
installation method.

Hot swapping an AT-AR040

Caution You cannot install PICs into an AT-AR040 NSM that has power applied to
it. This includes NSMs that have been deactivated using the hot swap button, but not
physically removed from the switch or router. To ensure that all power is removed
from the NSM bay, you must either physically remove it from the switch or router
using the hot swap method, or disconnect all power sources to the switch or router.

If you are installing an AT-AR040 NSM and you have PICs to install, follow the Port
Interface Card Installation and Safety Guide
. You can download this document from

www.alliedtelesis.com/support/software/

. If there are more PIC bays than PICs, use

the bays on the switch or router base unit first, then fill the NSM PIC bays starting
with bay 0.

You can hot swap the AT-AR040 NSM with PICs already installed in its PIC bays.
There is no need to remove the PICs before hot swapping. See the Network Service
Module Hardware Reference
for information on the operational characteristics of hot
swapped interfaces. You can download this document from

www.alliedtelesis.com/support/software/

.