Connecting the ground wire – Allied Telesis AT-iMG646PX-ON User Manual

Page 77

Advertising
background image

AT-iMG646xx Series Intelligent Multiservice Gateway and AT-EN646 Enclosure Installation Guide

Section II: Indoor Installation

77

Connecting the Ground Wire

To connect the ground wire, perform the following procedure:

1. Prepare an adequate length of 14AWG stranded grounding wire for the

ground connection.

2. Strip 0.25 in. (.635 cm) of insulation from the ground wire and crimp it

into the ground wire ring lug.

3. Secure the ring lug on the stud with a washer and #10-32 Kepnut, as

shown inFigure 50.

Figure 50. Securing the Ground Wire Lug

4. Trim and connect the other end of the ground wire to any ground point

according to National Electrical Codes.

1173