Chapter 3, Troubleshooting, Chapter 3 troubleshooting – Allied Telesis AT-MC104LH User Manual

Page 37

Advertising
background image

27

Chapter 3

Troubleshooting

Follow the guidelines below to test and troubleshoot the installation in the
event a problem occurs.

If the PWR LED is OFF, do the following:

ˆ

If the unit is installed on a desktop, check to be sure that the power
adapter is securely connected to a power outlet and that the power
adapter cable is securely connected to the back of the media
converter.

ˆ

If the unit is installed in an AT-MCR12 chassis, check that the unit is
fully seated in the slot.

ˆ

Verify that the power outlet has power by connecting another device
to it.

ˆ

Try using another power adapter of the same type that came with
your media converter.

If the LINK LED for the twisted pair port is OFF, do the following:

ˆ

Check that the end-node connected to the port is powered ON and is
operating properly.

ˆ

Check that the twisted pair cable is securely connected to the twisted
pair port on the media converter and on the remote end-node.

ˆ

Make sure that the twisted pair cable does not exceed 100 meters
(328 feet) and that you are using Category 5 or better.

ˆ

Verify that both end-nodes connected to the media converter are
operating at the same speed. Both must be operating at 100 Mbps.

Advertising