Allied Telesis AT-CM70S User Manual

Page 99

Advertising
background image

Converteon Media Converter Line Cards Reference Guide

99

Stand-Alone – Converteon™ Module Configured for Link Test

Figure 49 on page 98 shows a stand-alone configuration for a
Converteon™ line card (Module A) that has been configured for the Link
Test mode. Refer to “Link Test” on page 44 for configuring the module of
the Link Test mode. Module A is connected to an AT-8524M (Switch 1)
with a copper cable and to an AT-8516F/SC (Switch 2) with a dual fiber
cable.

Table 27 shows the Link (LK) LED status for each of the ports involved
when the cables are connected and disconnected from Module A's ports.

Table 27. Stand-Alone – Converteon™ Module in Link Test Mode

Network

Device

Port

Link

Converteon™ Module Cable Status

All Cables

Connected

Copper Cable

Switch 1 to

Module A -

Disconnected

Module A

Transmit/

Receive

Fiber Cable

Disconnected

Port
LINK
Status

Switch 1

Copper
LK LED

ON

OFF

ON

Converteon™
Module A

Copper
LK LED

ON

OFF

ON

Fiber
LK LED

ON

ON

OFF

Switch 2

Fiber
LK LED

ON

ON

OFF

Advertising