Fiber optic port specifications – Allied Telesis AT-FS202SC/FS1 User Manual

Page 48

Advertising
background image

Appendix A: Technical Specifications

38

Fiber Optic Port Specifications

Table 8. Fiber Optic Loss Specifications (Benchmarks)

Fiber Type

1

1. MMF = Multimode Fiber / SMF = Single-mode Fiber

Fiber Optic

Diameter

(microns)

Optical

Wavelength

Typical

Loss

Factor

(dB/km)

Band-width

(Mhz * km)

MMF

50/125

1310 nm

1.00

400

62.5/125

1310 nm

1.00

500

SMF

9/125

1310 nm

0.40

N/A

1550 nm

0.30

N/A

Table 9. Fiber Optic Transmitter

Model

Fiber Optic

Type

1

1. MMF = Multimode Fiber / SMF = Single-mode Fiber

Optical

Wavelength

Launch Power (dBm)

2

2. The launch power is measured at one meter from the transmitter.

Min.

Avg.

Max.

AT-FS201
and
AT-FS202

50/125 MMF

1310 nm

-22.5

-20.3

-14.0

62.5/125 MMF

1310 nm

-19.0

-16.8

-14.0

AT-FS202SC/FS1

9/125 SMF

1310 nm

-15.0

-11.5

-8.0

Table 10. Fiber Optic Receiver

Model

Fiber Optic

Type

1

1. MMF = Multimode Fiber / SMF = Single-mode Fiber

Optical

Wavelength

Receive Power (dBm)

Min.

Typical

Saturation

AT-FS201
and
AT-FS202

50/125 MMF

1310 nm

-31.8

-34.5

-14.0

62.5/125 MMF

1310 nm

-31.8

-34.5

-14.0

AT-FS202SC/FS1

9/125 SMF

1310 nm

-31.0

-31.0

-8.0

Advertising
This manual is related to the following products: