Allied Telesis AT-FS203 User Manual

Page 35

Advertising
background image

AT-FS200 Series Installation Guide

25

Table 10 Fiber Optic Receiver

Model

Fiber
Type

Fiber
Optic
Diameter
(microns)

Optical
Frequency
(nm)

Receive Power (dBm)

Min.
Sensi-
tivity

Typical
Sensi-
tivity

Satura-
tion

AT-FS201 &
AT-FS202

MMF

50/125

1310 nm

-31.8

-34.5

-14.0

MMF

62.5/125

1310 nm

-31.8

-34.5

-14.0

AT-FS201ST/FS1 &
AT-FS202SC/FS1

SMF

9/125

1310 nm

-31.0

-31.0

-8.0

AT-FS201ST/FS2 &
AT-FS202SC/FS2

SMF

9/125

1310 nm

-35.0

-38.0

0.0

AT-FS201ST/FS3 &
AT-FS202SC/FS3

SMF

9/125

1310 nm

-37.0

-37.0

-3.0

Table 11 Fiber Optic Datalink

Model

Fiber Type

Min.
Power /
Link
Budget
(dB)

Avg.
Signal
Loss
(dB)

Min.
Distance
Specs.

1

1. The recommended minimum range is stated in all cases where the maximum trans

mitter output power exceeds the receivers saturation level. This is to prevent blind-
ing or burning out of the optical receiver on the far-end node.

Max.
Distance
Specs.

AT-FS201 &
AT-FS202

50/125 MMF

13.00

18.70

0

2 km
(1.25 mi)

62.5/125
MMF

16.80

22.50

0

2 km
(1.25 mi)

AT-FS201ST/FS1 &
AT-FS202SC/FS1

9/125 SMF

16.00

19.50

0

15 km
(9.4 mi)

AT-FS201ST/FS2 &
AT-FS202SC/FS2

9/125 SMF

30.00

35.00

0

40 km
(25 mi)

AT-FS201ST/FS3 &
AT-FS202SC/FS3

9/125 SMF

33.00

35.00

15 km
(9.4 mi)

75 km
(46 mi)

Advertising