Determining the switch location, Configuration rules, Installing the switch – Allied Telesis AT-8550 User Manual

Page 22: Rack mounting

Advertising
background image

Determining the Switch Location

2-2

Determining the Switch Location

The switches are suited for use in the office, where it can be free-standing, or
mounted in a standard 19-inch equipment rack. Alternatively, the device can be rack-
mounted in a wiring closet or equipment room. Two mounting brackets are supplied
with the switch.

When deciding where to install the switch, ensure that:

" The switch is accessible and cables can be connected easily.

" Water or moisture cannot enter the case of the unit.

" Air-flow around the unit and through the vents in the side of the case is not

restricted. You should provide a minimum of 25 mm (1-inch) clearance.

" No objects are placed on top of the unit.

" Units are not stacked more than four high if the switch is free-standing.

Configuration Rules

The connectors, supported media types, and maximum distances for the switches are
described in Chapter 1.

Note

For more information on 1000Base-SX and 1000Base-LX link characteristics, refer
to IEEE Draft P802.3z/D4.2, Table 2-1 and Table 38-6.

Installing the Switch

The switch can be mounted in a rack, or placed free-standing on a tabletop.

Rack Mounting

Each switch is two rack units high and will fit in most standard 19-inch racks.

Note

The rack mount kits must not be used to suspend the switch from under a table or
desk, or attach it to a wall.

To rack mount the switch, follow these steps:

1.

Place the switch the right way up on a hard flat surface, with the front facing
toward you.

2.

Locate a mounting bracket over the mounting holes on one side of the unit.