Fiber optic port specifications – Allied Telesis AT-MC1005/4 User Manual
Page 28
Technical Specifications
18
Fiber Optic Port Specifications
Table 5 and Table 6 list the specifications for the fiber optic port.
Table 5 Fiber Optic Port Specifications
Table 6 Launch and Receive Power Specifications
Model
Cable
Transmitter
Output Power
(dBm)
Optical
Wavelength
(nm)
Minimum
Receiver
Sensitivity
(dBm)
AT-MC1004
50/125 or 62.5/125
micron multimode
-4.0 to -9.5
850
-17.0
AT-MC1005/1
9/125 micron
single-mode
-3.0 to -9.0
1310
-20.0
AT-MC1005/2
9/125 micron
single-mode
-4.0 to 1.0
1310
-21.0
AT-MC1005/3
9/125 micron
single-mode
-4.0 to 1.0
1550
-21.0
AT-MC1005/4
1
1. For maximum performance of Gigabit Optical Datalinks for distances greater than 40 km (24.8 mi) and operating
within the 1550 nm optical spectrum, it is mandatory that the Single-mode Fiber (SMF) be rated as
non-dispersion-shifted, dispersion shifted, or non-zero dispersion shifted.
9/125 micron
single-mode
-3.0 to 2.0
1550
-23.0
Model
Launch Power (dBm)
Receive Power (dBm)
Min.
Avg.
Max.
Minimum
Sensitivity
Typical
Sensitivity
Saturation
1000Base-SX
AT-MC1004
-9.5
-6.0
-4.0
-17.0
-17.0
0.0
1000Base-LX
AT-MC1005/1
-9.0
-5.0
-3.0
-20.0
-20.0
-3.0
AT-MC1005/2
-4.0
-1.0
1.0
-21.0
-21.0
-3.0
AT-MC1005/3
-4.0
-2.0
1.0
-21.0
-21.0
-3.0
AT-MC1005/4
-3.0
0.0
2.0
-23.0
-23.0
-3.0