Fiber optic port specifications – Allied Telesis AT-MC1005/4 User Manual

Page 28

Advertising
background image

Technical Specifications

18

Fiber Optic Port Specifications

Table 5 and Table 6 list the specifications for the fiber optic port.

Table 5 Fiber Optic Port Specifications

Table 6 Launch and Receive Power Specifications

Model

Cable

Transmitter
Output Power
(dBm)

Optical
Wavelength
(nm)

Minimum
Receiver
Sensitivity
(dBm)

AT-MC1004

50/125 or 62.5/125
micron multimode

-4.0 to -9.5

850

-17.0

AT-MC1005/1

9/125 micron
single-mode

-3.0 to -9.0

1310

-20.0

AT-MC1005/2

9/125 micron
single-mode

-4.0 to 1.0

1310

-21.0

AT-MC1005/3

9/125 micron
single-mode

-4.0 to 1.0

1550

-21.0

AT-MC1005/4

1

1. For maximum performance of Gigabit Optical Datalinks for distances greater than 40 km (24.8 mi) and operating

within the 1550 nm optical spectrum, it is mandatory that the Single-mode Fiber (SMF) be rated as
non-dispersion-shifted, dispersion shifted, or non-zero dispersion shifted.

9/125 micron
single-mode

-3.0 to 2.0

1550

-23.0

Model

Launch Power (dBm)

Receive Power (dBm)

Min.

Avg.

Max.

Minimum
Sensitivity

Typical
Sensitivity

Saturation

1000Base-SX

AT-MC1004

-9.5

-6.0

-4.0

-17.0

-17.0

0.0

1000Base-LX

AT-MC1005/1

-9.0

-5.0

-3.0

-20.0

-20.0

-3.0

AT-MC1005/2

-4.0

-1.0

1.0

-21.0

-21.0

-3.0

AT-MC1005/3

-4.0

-2.0

1.0

-21.0

-21.0

-3.0

AT-MC1005/4

-3.0

0.0

2.0

-23.0

-23.0

-3.0

Advertising