OM-KTT/KTC-E 15

Maintenance

WARNING

TO AVOID INJURY, READ AND FOLLOW

ALL PRECAUTIONS STATED ON THE

LABEL OF THE WATER TREATMENT

COMPOUND.

4.

Jacket Filling

Every day, before you turn on the unit, make sure the water level is

approximately in the center of the water gauge glass. The jacket was filled at

the factory with the proper amount of treated water, and is airtight, but over

time steam may be vented and water lost.

From time to time, you may need to restore the water to its proper level. The

procedure for adding water follows.

a.

If you are replacing water lost as steam, use distilled water. Do not use

tap water. If you are replacing treated water that was drained from the

jacket, prepare more treated water as directed below.

b.

Allow the kettle to cool completely. Remove the pipe plug from the

jacket fill assembly. Pour in the distilled or treated water. Using a

funnel will help you in this process. Hold the pressure relief valve open

while you pour, to let air escape from the jacket. Continue adding

water until the water level rises to the center of the round sight glass.

c.

Air that gets into the jacket during the filling operation must be

removed, because it will make heating less efficient. Follow the

procedure in Jacket Vacuum/Removing Air From Jacket above, to

restore a negative pressure reading.

5.

Water Treatment

a.

Fill a mixing container with the amount of water required. Use only

distilled water.

b.

Hang a strip of pH test paper on the rim of the container, with about 1

inch of the strip below the surface of the water.

c.

Stir the water continuously, while you slowly add water treatment

compound until a color between indicating a pH of 10.5 and 11.5 is

reached. (Shown on the pH test kit chart.) Judge the pH by frequently

comparing the test strip with the color chart provided in the pH test kit.

If there is a problem distinguishing color, use a pH meter.

d.

Use a measuring cup to add the compound so that you may record the

exact amount used.

e.

The amount may be used again, if the same water sources and

compound are used in the future. However, it is best to check the pH

each time treated water is prepared.

Model

Kettle Capacity

Jacket Capacity

5E-KTT, 5E-KTC

5 gal (20 qt) 18.9 liter

7 quart 6.6 liter

6E-KTT, 6E-KTC

6 gal (24 qt ) 22.7 liter

7 quart 6.6 liter

10E-KTT, 10E-KTC

10 gal (40 qt) 37.8 liter

9 quart 8.5 liter

12E-KTT, 12E-KTC

12 gal (48 qt) 45.4 liter

9 quart 8.5 liter

The pressure relief valve and fill

plug are located directly behind the

pressure/vacuum gauge.