INSTALLATION INSTRUCTIONS (Continued)



9. A control box with a power supply equivalent to electrical rating of the unit should be

located nearby. A waterproof electrical connection for the power supply to the unit
must be provided.


10. The relief valve on the kettle must not be adjusted or closed off as it is set to relieve

excess pressure in the kettle.


11. If large amounts of water accumulate in the steam line, it will be necessary to install

one or more ball float traps (supplied by others) in the line to eliminate the water.


12. A steam line pressure gauge (supplied by others) is also recommended to determine

the actual amount of steam coming to the kettle.


13. Turn unit on when electrically connected, then check for proper operation.