Figure 2

Install retention posts



Figure 3

Purge the air from the water-block,

by pointing the discharge spigot

upwards

1. Preparing

your

Motherboard

Installation of the retention posts requires removal of the motherboard from the chassis.

Remove the existing heat sink

Carefully clean the CPU.

2.

Retention Posts installation
Install all the washers in the precise sequence shown in figure 1. The sequence is: Philips screw,
black fiber-washer, motherboard, black fiber-washer, lock-washer, and hex-nut. Using fiber-
washers on either side of the motherboard is critical to prevent shorting of the motherboard. Once
the posts are securely fastened to the motherboard, you can re-install it inside the chassis.
Completed installation is also shown in figure 2.


3. Purging

the

water-block

The geometry and keep-out areas surrounding socket LGA 775 require that the MCW6000 & 6002
water-blocks be installed with the discharge spigot facing downwards. In a vertical orientation, this
prevents the water-block from purging appropriately. There are two possible strategies to purge
the water-block: :

a.

You can fill-up the circuit and purge the water-block of any air trapped inside BEFORE
fastening it to the motherboard, as shown in figure 3.
TIP! If you are using a 12 volts pump feeding from the computer power-supply, do not start-
up the computer while the cooler is not installed on the CPU
. Disconnect the power
supply from the motherboard, and use a power supply tester to start it up independently. This
will allow you to run the pump by itself, and fill-up the circuit.

b. If you do not have a power-supply tester, you can install the water-block onto the

motherboard, but you will need to fill-up the circuit with the computer laying flat on a table, as
the water-block purges correctly when lying horizontally.

4.

Connecting the water-block(s) to the cooling circuit:

Carefully identify the direction of the flow in your circuit. For the MCW6000 to operate
properly, the spigot located at the center of the water-block MUST BE USED AS THE INLET
(see figure 1 “INLET” spigot).

Attaching the tubes: the MCW6000™ and 6002 series ship with worm-drive type hose
clamps. Secure the tubes as shown in the picture to the right, and tighten the clamps firmly.

Type of Coolant: being entirely made of copper, the MCW6000™ series may be used with
pure water, and do not necessitate the use of anti-corrosion agents. The use of an algaecide
is nonetheless recommended in any liquid cooling system, and our HydrX™ additive also
performs such function.

5.

Applying thermal compound to the CPU
Lightly coat the CPU with the provided Céramique™ thermal compound. Follow this link

http://www.arcticsilver.com/ceramique_instructions.htm

for detailed instructions.

Rub some compound in base of water-block

first, and then clean off with lint-free cloth.

Apply small amount of compound on

the CPU heat spreader


6.

Fasten water-block to motherboard
Place the water-block on the CPU with the step side above the socket lever. The hold-down plate
is asymmetric in order to locate the water-block precisely inside of the “keep out” areas. This
guarantees full compatibility of the water-block with all LGA 775 motherboards. Insert nylon
shoulder washer and spring on each post, and fasten the acorn nuts in a cross pattern.
Installation is complete!

Figure 4

Install water-block, hold-down plate,

and fasten the spring-nut assemblies’

in a cross pattern (finger tight).

IMPORTANT DISCLOSURES

While all efforts have been made to provide the most comprehensive tutorial possible, Swiftech assumes no liability expressed or implied for any damage(s) occurring to your components as a result of

using Swiftech cooling products, either due to mistake or omission on our part in the above instructions, or due to failure or defect in the Swiftech cooling products.

WARRANTY

Our products are guaranteed for 12 months from the date of delivery to the final user against defects in materials or workmanship. During this period, they will be repaired or have parts replaced

provided that: (I) the product is returned to the agent from which it was purchased; (II) the product has been purchased by the end user and not used for hire purposes; (III) the product has not been

misused, handled carelessly, or other than in accordance with any instructions provided with respect to its use. This guarantee does not confer rights other than those expressly set out above and does

not cover any claims for consequential loss or damage. This guarantee is offered as an extra benefit and does not affect your statutory rights as a consumer.

Copyright Swiftech 2004 – All rights reserved – Last revision date: 10-29-04
Rouchon Industries, Inc., dba Swiftech – 1703 E. 28

th

Street, Signal Hill, CA 90755 – Tel. 562-595-8009 – Fax 562-595-8769 - E Mail:

[email protected] – URL:

http://www.swiftnets.com

- Information subject to change without notice

Advertising