RS232/Command Line Interface Guide

Communication Configuration
To control this projector from an RS-232 control system, connect a null modem cable and set the control system serial port

settings to match the following communication configuration*:

RS-232 Port Settings
Setting Value
Bits per second

19,200

Data bits

8

Parity None
Stop bits

1

Flow control

None

Emulation VT100

Command Format

All commands consist of 3 alpha characters followed by a request, all enclosed in parentheses. The request can be a read

request (indicated by a "?") or a write request (indicated by 1 to 4 ASCII digits).

A read request example:

(AAA?) where

( starts the command

AAA denotes the command

? denotes the read request

) ends the command

A read command returns the range and the current setting, for example:

Read Command Examples

Function Command

Response

Brightness (BRT?)

(0-22,

10)

Volume (VOL?) (0-80,

0)

Lamp Hours

(LMP?)

(0-9999, 421)

A write request example:

(AAA####) where

( starts the command

AAA denotes the command

#### denotes the value to be written

(leading zeros not necessary)

) ends the command

Some commands have ranges, while others are absolute. If a number greater than the maximum range is received, it is

automatically set to the maximum number for that function. If a command is received that is not understood, a "?" is

returned. With absolute settings, "0" is off, 1-9999 is on. The one exception is the Power command, where 0 is off and 1 is

on.

To assure the projector can process a command, wait 3 seconds before entering the next command.