4.

Connecting the pump to the circuit:

The pump’s inlet and outlet are 3/8” in outside diameter. Use with 3/8” ID (1/2” OD) tubing, or 10mm
ID (12mm OD) for Europe.

5. Performance

&

Specifications

Nominal voltage

12 V DC

Operating voltage range

9 to 13.2 VDC

Nominal power (@ 12 V)

8.3 W

Nominal current (@ 12 V)

.69 amps

Motor type

Electronically commutated,
brushless DC, spherical
motor

Nominal head (@ 12 V)

13.05 ft (4 m)

Nominal discharge (@ 12 V)

~ 92.4 GPH (350 LPH)

Connection size

3/8" barbs (10mm)

Maximum pressure

22 PSI (1.5 BAR)

Temperature range

Up to 140°F (60°C)

Electrical connector

Molex 4 pin

Weight

7.3 oz (207 gr.)

Our noise measurement (non
lab environment)

24 ~ 26 dBA in a quiet room
@ 2'

MTBF (Mean Time Between
Failures)

50,000 Hours

RPM sensor

3-pin connector

6.

Permanent installation to the chassis, and exploded view

Drill two 0.312”
(8mm) holes into
panel, 2.52” (64
apart. Snap
grommet into each
hole. Tighten the
provided screws
until the pump
neoprene pad is
slightly and evenly
compressed by
approximately 1/8”
(2~3mm) or less.

mm)

MCP350 PUMP

∅0.313"

(8mm)

Grommet

Washer

#6 x 7/8"

Philips screw

2.52"

(64mm)

Neoprene
pad

DISCLAIMER:

Swiftech assumes no liability whatsoever, expressed or implied, for the use of this product, and more specifically for

any, and all damages caused by the use of this product to any other devices in a personal computer, whether due to product failure,
leak, electrical shorts, and or electro-magnetic emissions. WARRANTY: This product is guaranteed for a period of 24 months from
date of purchase for defects in material, and workmanship. Guarantee consists of replacing defective parts with new or reconditioned
parts. Guarantee is considered void in case of improper use (*)(**)(***), handling or negligence on the part of user. Original invoice
showing date and place of purchase is required for exercise of the warranty.

(*) WARNING: DO NOT ATTEMPT TO RUN THIS PUMP DRY.

THIS WILL CAUSE IMMEDIATE AND PERMANENT DAMAGE TO THE PUMP. (**) EXCESSIVE WEAR DUE TO INNAPROPRIATE FLUIDS. (***)
EXCESSIVE RESTRICTION TO THE PUMP’S INLET

Rouchon Industries, Inc., dbA Swiftech™ – 1703 E. 28

th

St, signal Hill, CA 90755, USA – T (562) 595-8009 – F (562) 595-8769 – All

content Copyright Swiftech 2004 – Last edited 2-1-05 – Subject to revision without notice

- 17 of 39 -

Advertising