6.

Maintenance operations: impeller housing assembly to pump’s body

The impeller housing assembly may be rotated or replaced by following the procedure below:

Disconnect the pump from the system and drain any remaining fluid.

Unscrew the 4 Phillips head stainless steel screws holding the black plastic pump head to the motor, and lift the complete
housing assembly away from the motor.

Rotate the assembly in the desired position and re-insert the 4 stainless steel screws. Gently tighten the screws in a cross
pattern until all are snug. Note that extreme pressure is not needed as the pump housing is sealed with an o-ring.

It is not recommended to take the impeller housing assembly apart.

Rouchon Industries, Inc., dbA Swiftech™ – 1703 E. 28

th

St, signal Hill, CA 90755, USA – T (562) 595-8009 – F (562) 595-8769 – All content

Copyright Swiftech 2004 – Last edited 5-5-04– Subject to revision without notice