98

SPEKTRUM DX6i • RADIO PROGRAMMING GUIDE

RANGE ChECKING A MODEl

Rotate the roller to highlight RANGE and press the roller to access the range function.

Reduce photo to 13.5%

RANGE CHECK

CHECK INH

List

hOw TO RANGE TEST ThE DX6I

RANGE TESTING ThE DX6I

1. With the model on and resting on the ground, stand 30 paces (approx. 90 feet) away from the model.
2. Face the model with the transmitter in your normal flying position. Place the transmitter in the range

test screen (see above) and pull and hold the trainer switch on the top of the transmitter. This causes

reduced power output from the transmitter.

3. You should have total control of the model with the trainer switch pulled at 30 paces (90 feet).

Pull and hold the trainer switch

30 paces (90 feet)

4. If control issues exist, call the Horizon Product Support Team at 1-877-504-0233 for further assistance.