Aube Technologies TH115 A User Manual

Th115 a/f/af, User guide, Description

Advertising
background image

TH115 A/F/AF

400-115-003-B 27/2/07 1/2

Aube’s TH115 programmable thermostats have three temperature
control modes:

1

Place the switch in Standby to cut power to the heater when not in use (e.g., in the sum-

mer). This will not affect the time and temperature settings.

2

If your thermostat is installed on a power base equipped with a ground fault protection,

to reset the ground fault protection, switch the thermostat to Standby and back to On.

3

The thermostat displays the percentage of heating time required to maintain the desired

temperature. For example, is displayed when heating is activated 40 percent of the
time.

4

GFI appears when the ground fault protection has tripped.

Some thermostat configurations can be modified via
switches on the back of the faceplate (control module).
Default (factory) settings are inside the gray cells.

n

Refer to the installation
instructions of the power
base.

o

Insert the tabs at the top of
the control module in the slots
at the top of the power base.

p

Secure the control module
using the captive screw
underneath the base.

NOTE: Keep the thermostat's air vents clean and unobstructed at all times.

n

Press the Hour button to set the hour.

o

Set the Min button to set the minutes.

p

Set the Day button to set the day.

q

Press Mode/Ret to exit.

Daylight Savings Time

The thermostat can automatically re-adjust its clock at Daylight Sav-
ings Time changeover. When this function is enabled (On), the ther-
mostat switches to Daylight Savings Time on the second Sunday of
March and to normal time on the first Sunday of November.
NOTE: The function is disabled (default setting) when the clock loses
its setting.

n

Press the Day button (3 seconds) until DLS appears
on the screen.

o

Press the

to toggle between On (enabled) and Off

(disabled).

p

Press the Day button briefly. The year setting is dis-
played.

q

Press the

to set the current year.

r

Press the Day button briefly. The month setting is dis-
played.

s

Press the

to set the current month.

t

Press the Day button briefly. The date setting is dis-
played.

u

Press the

to set the current date.

v

Press Mode/Ret to exit.

The display illuminates for 12 seconds when the backlight button is
pressed.
When either of the

buttons is pressed, the display also illuminates

for 12 seconds. The setpoint temperature appears for 5 seconds,
then the actual (measured) temperature is displayed.

6.1

Setpoint Temperature

The thermostat normally displays the actual (measured) temperature.
To view the setpoint, press one of the

buttons once. The setpoint

will appear for the next 5 seconds.
To change the setpoint, press one of the

buttons until the desired

temperature is displayed. To scroll faster, press and hold the button.

6.2

Preset Temperatures

The thermostat has 3 preset temperatures:



Comfort temperature



Economy temperature



Vacation temperature

To use a preset temperature, press the corresponding button. The
corresponding icon , or will be displayed.
The following table shows the intended use and the default setting of
each of the preset temperatures.

To store a preset temperature:

n

Set the desired temperature using the

buttons.

o

Press and hold the corresponding button until the corresponding
icon is displayed.

n

Description

1.

A mode:



controls the ambient air temperature

F mode:



controls the floor temperature using an
external temperature sensor

AF mode:



controls the ambient air temperature



maintains the floor temperature within desired
limits using an external temperature sensor

Display

% of heating time

1 to 24% 25 to 49% 50 to 74% 75 to 99%

100%

o

Configuration

2.

#

Configurations

UP

DN

1

Display format

°F / 12 h

°C / 24 h

2

Early Start

a

a.

Early Start can be used in Automatic mode only. When this function is enabled, the
thermostat calculates the optimal time to start heating in order to obtain the desired
temperature by the set time. The thermostat re-assesses the start time daily based
on the previous day’s results.

Enable

Disable

3

Temperature control mode

b

b.

To select the F mode, place the switch in the F position. To select the AF mode,
place the switch in the AF position and ensure that the remote temperature sensor
is connected to the thermostat. To select the A mode, place the switch in the AF
position and ensure that the remote temperature sensor is NOT connected to the
thermostat.

F

AF

p

Installation

3.

On/Standby switch

1

and GFCI reset

2

Day and time
settings

Temperature
adjustment buttons

Program button

Mode selection /
program exit

Temperature display

Mode display

Period display

Temperature
preset buttons

Time and day display

Percentage of
heating time

3

Backlight button

Program
clear button

Preset temperature
indicator

Appears when the
setpoint is displayed

Temperature control
mode indicator

Ground fault indicator

4

Power base

Control module

Air vents

Air vents

q

Clock and Day Setting

4.

r

Backlight

5.

s

Temperature Adjustment

6.

Icon

Intended use

A/AF modes

F mode

Comfort
(when at home)

21 °C (70 °F)

28 °C (82 °F)

Economy
(when asleep or away from home)

17 °C (63 °F)

20 °C (68 °F)

Vacation
(during prolonged absence)

10 °C (50 °F)

10 °C (50 °F)

TH115 A/F/AF

User Guide

Programmable Thermostat

400-115-003-B (TH115B_AF) ENG.fm Page 1 Tuesday, February 27, 2007 2:55 PM