Chapter 3: Option Selection


Each channel has a jumper configurable filter option.

3.

90

"

6.90"

NO FILTER

FILTER

FL

T

0

FL

T1

5

FL

T1

6

FL

T

3

1

FL

T3

2

FL

T4

7

Figure 3-1: Option Selection Map

Filter Response Switch


Jumpers are used to select input filtering on a channel-by-channel basis (see Figure 3-1). When jumper
FLT0 is installed, filtering is introduced for input bit 0, FLT1 for bit 1, and so on. The tables below describe
filtering for Port 0. Ports 1 and 2 follow the same pattern with Port 1 having FLT16-31 (Bits 16-31) and
Port 2 having FLT32-47 (Bits 32-47). Filtering provides a slower response for DC signals as described
previously and must be used when AC inputs are applied.

JUMPER SELECTION

Bit Filtered

JUMPER SELECTION

Bit Filtered

FLT-0
FLT-1
FLT-2

...

Bit 0
Bit 1
Bit 2

...

FLT-8
FLT-9

FLT-10

...

Bit 8
Bit 9

Bit 10

...