Electrical connection – Indesit PI640 A GB User Manual

Page 3

Advertising
background image

GB

3

Front

40

Clamp Position for

Back

H=40mm top

! Use the clamps contained in the "accessory kit."

• In the event the cooktop is not installed above a

built-in oven, a wood panel must be inserted as

insulation. This panel must be placed at least 20

mm from the bottom of the cooktop itself.

Ventilation

When installing the cooktop above a built-in oven, the

oven should be placed on two wooden strips; in the

case of a joining cabinet surface, remember to leave a

space of at least 45 x 560 mm at the back (see

picture).

! The hob can only be installed above built-in

ovens provided with cooling ventilation.

Electrical connection

The cooktops fitted with a tripolar electrical supply

cord are designed to be be used with alternating

current according to the indications on the rating plate

located under the cooktop. The earthing wire can be

identified by its yellow-green colour.

In the case of installation over a built-in electric oven,

the electrical connections for the cooktop and oven

should be independent, not only for safety purposes,

but also to facilitate removal of one or both in the

future.

Electrical Connection for Gas Cooktop

Fit the supply cord with a standard plug for the

demand rate indicated on the rating plate or connect it

directly to the electrical mains. In the latter case, a

single pole switch must be placed between the

appliance and the mains, with a minimum opening

between the contacts of 3 mm in compliance with

current safety codes (the earthing wire must not be

interrupted by the switch). The power supply cord

must be positioned so that it does not reach a

temperature in excess of 50°C above room

temperature at any point.

! The installer must ensure that the correct electrical

connection has been made and that it is compliant

with safety regulations.

Before making the actual connection, make sure that:

• The fuse and electrical system can withstand the

load required by the appliance;

• That the electrical supply system is equiped with an

efficient earth hook-up according to the norms and

regulations prescribed by law;

• That the plug or switch is easily accessible.

! The wires in the mains lead are coloured in

accordance with the following code:

Green & Yellow

- Earth

Blue

- Neutral

Brown

- Live

As the colours of the wires in the mains lead may not

correspond with the coloured markings identifying the

terminals in your plug, proceed as follows:

Connect the Green & Yellow wire to the terminal

marked “E” or

or coloured Green or Green &

Yellow.

Connect the Brown wire to the terminal marked “L” or

coloured Red.

Connect the Blue wire to the terminal marked “N” or

coloured Black.

! The cable must not be bent or compressed.

! The cable must be checked regularly and replaced

by authorised technicians only (see Assistance).

!

The manufacturer declines any liability should

these safety measures not be observed.