Malfunctions:

The green POWER indicator light does

not illuminate.

The motor does not start.

The indicator lights are on but the light

is dim.

a) The alarm sounds.

b) The alarm sounds and the two

yellow indicator lights flash.

c) The alarm sounds and the two

yellow indicator lights as well as the

green one flash.

The green POWER indicator light

flashes.

The refrigerator and the freezer do not

cool well.

The food inside the refrigerator is

beginning to freeze.

The motor runs continuously.

The appliance makes a lot of noise.

Some of the external parts of the

refrigerator become hot

Possible causes / Solutions:

• The plug has not been inserted into the electrical socket, or not far

enough to make contact, or there is no power in the house.

• The appliance comes with a motor protection control (see Start-up and use).

• Pull out and reverse the plug before putting it back in the socket.

a) The refrigerator door has remained open for more than two minutes (the

buzzer will stop sounding when you shut the door) or the correct

switching-off procedure was not followed (see Maintenance).

b) The temperature in the freezer is too high. Check the quality of the food

products and dispose if necessary.

c) The temperature in the freezer has reached a dangerous level. The

food must be disposed immediately.

b/c) In the first case the freezer will maintain a temperature of about 0°C

so that the food does not re-freeze. In the second case, however, the

temperature will remain at approximately -18°C.

To turn off the acoustic signal open and close the refrigerator door.

To restore normal operation bring the FREEZER OPERATION knob

setting to (off) and turn the appliance on again.

• The appliance is not operating correctly. Contact the Technical

Assistance Centre.

• The doors do not close properly or the seals are damaged.

• The doors are opened too frequently.

• The OPERATION knobs are not on the correct setting (see Description).

• The refrigerator or the freezer have been over-filled.

• The REFRIGERATOR OPERATION knob is not on the correct setting

(see Description).

• The food is in contact with the back inside wall of the refrigerator.

• The SUPER FREEZE button has been pressed (rapid freezing): the

yellow SUPER FREEZE light is on (see Description).

• The door is not closed properly or is continuously opened.

• The outside ambient temperature is very high.

• The appliance has not been installed on a level surface (see

Installation).

• The appliance has been installed between cabinets that vibrate and

make noise.

• The internal refrigerant makes a slight noise even when the compressor

is off. This is not a defect, it is normal.