Installation, Electrical hook up, Air exhaust – Indesit IHP-7.5-C-M-IX User Manual

Page 37: Filter or ducted, Technical data

Advertising
background image

GB

37

Installation

The installation procedure is illustrated in the first pages

of this manual.

The installation must be done by a qualified technician.

Electrical hook up

The mains voltage must match that given on the ratings

label inside the hood itself. If the hood has a power plug,

connect the hood to an easily accessible regulatory power

socket. If it does not (direct connection to the mains), or the

socket is not easily accessible, install a two-pole regulatory

switch to enable total disconnection from the mains in case

of category III overvoltage, as required by the installation

regulations.

Caution! Always check that the mains cable is hooked

up properly and check that it operates correctly before

reconnecting the hood to the mains.

Air exhaust

(for ducted units)

Connect the hood to a duct and wall exhaust hole of a

diameter equal to that of the air outlet flange. Using a smaller

diameter tube and exhaust hole reduces the extraction

capacity of the hood and also increases its running noise.

The manufacturer is not liable for any consequences of

doing so.

! Use the shortest duct required to achieve the purpose.
! Use a duct with as few bends as possible
! Avoid suddenly changing the diameter of the duct.
! The duct must have as smooth an inner surface as

possible.
! The duct must be made of regulatory material.
! Do not connect the hood to flues carrying combustion

fumes from other equipment (boilers, chimneys, stoves,

etc.).
! Observe the instructions of the competent authorities in

relation to the air exhaust. The air being exhausted may not

be exhausted into a wall cavity unless the cavity in question

is specifically intended for this purpose.
! Equip the room with air intakes to prevent the hood creating

suction pressure in the interior (this must not exceed 0.04

mbar).
! The manufacturer is not liable for any consequences of

failure to observe these instructions.

Filter or ducted?

! Your hood is supplied as a ducted unit.

If you wish to use it as a filter unit, you must install the proper

ACCESSORY KIT.

Note: If supplied with the hood, the accessory active

charcoal filter unit may already be installed.

Instructions for transforming the hood from the ducted to the

filter version are given in this manual (see “Filter version”).

Ducted version

The hood purifies the air and expels it outdoors via an exhaust

duct (dia. 150mm) connected to its outlet flange. The diameter

of the exhaust tube must be equal to that of the outlet flange.

Caution! The exhaust duct is not supplied and must be

purchased separately.

When routed horizontally, the tube must be angled slightly

upwards (around 10°) to enable the air to be conveyed

outdoors more easily. If the hood is fitted with charcoal

filters, they must first be removed.

Filter version

The hood purifies the air and returns it to the room. This

version of the hood requires installation of an accessory

active charcoal filter unit.

This version requires an air deflector, a reduction adapter

and the charcoal filter/s. The top tube must have its air

outlet slots uppermost.

Technical data

Model

Height

(cm)

Width

(cm)

Depth

(cm)

dia. of

exhaust tube

(cm)

PYRAMID 60cm

61-82

59.8

50

15/12

PYRAMID 70cm

61-82

69.8

50

15/12

PYRAMID 90cm

61-82

89.9

50

15/12

Model code

Bulb (V) Bulb draw (W) Total draw (W)

IHP 6.5 C M IX

IHP 6.5F C M IX

IHP 6.5F C M K

IHP 9.5F C M IX

IHP 9.5 C M IX

IHP 7.5 C M IX

Halogen

2 x 25

160

Power

Voltage

Cap

Dimensions

Halogen 25 W

2 x 25 W

230 V

G9

L40xØ14

Halogen 20 W

2 x 20 W

12 V

G4

L30xØ10

LED

*

Risk Group 1 according to Standard EN 62471

The hoods are conforming to the following EC

Directives:

• “Low voltage” Directive 2006/95/EC (12-12-2006)

• “EMC” Directive 2004/108/EC (15-12-2004)

*

Only available in certain models

Advertising
This manual is related to the following products: