ROTHENBERGER ROSPIMATIC User Manual

Page 14

Advertising
background image

10

ENGLISH

2

Technical Data

Nominal consumption ....................................... 230 V

Performance ..................................................... 630 W

Speed ............................................................... 0

– 950 1/min clockwise

Spiral rod diameter ........................................... Ø 8 mm

Max. spiral rod diameter ................................... 7,5 m

Weight .............................................................. approx. 5 kg

Class of protection ............................................ II

Protection type .................................................. IP 20

Operation category ........................................... S3 10%

Typical evaluated acceleration

in hand/arm area ...............................................

< 2,5 m/s²

Typical A-rated sound level:

Noise pressure level (L

pA

) ................................. 83 dB (A) ¦ K

pA

3 dB (A)

Sound power level (L

WA

) ................................... 94 dB (A) ¦ K

WA

3 dB (A)

The noise level during operation can exceed 85 dB (A). Wear hearing protection!

Measured values determined in accordance with EN 60745-1:2010.

Subject to technical modifications!

3

Function of the Unit

3.1

Overview

(A)

1

Spiral rod holder

4

Pressure sensor

2

Drive

5

Spiral

3

Control handle

3.2

Operating

(B)

 Plug mains plug into power supply.

A heavy starting torque is produced when the machine starts running! Exer-
cise care when starting up the machine, i.e. select a low speed and increase if
required!

Inserting the spiral into the pipe:
 Tighten the pressure sensor (4) (+) and set the control handle (3) to forward motion (push

handle in the direction of the spiral container (1). The feeder is regulated continuously (for-
wards, neutral and backwards) by means of the control handle (3).

Only tighten the pressure sensor (4) sufficiently to ensure that the spiral can no longer be
pulled by hand from the spiral container.

There must be a distance of approx. 20 cm between the cleaning equipment and the
pipe opening.

 Use one hand to grip the control handle (3) on the cleaning equipment. Use the other hand

to start the drill (2) moving slowly and rotating to the right.

The spiral should bore its way into the existing blockage and should not be pressed
in.

 Increase the speed depending on the cleaning problem.

Advertising