3.5

Changing saw blades

Always use perfectly sharpened saw blades that are suitable for the application.

Saw blades that are cracked or have changed shape are hazardous and must not

be used!

Pull the electrical plug from the socket.

Open the safety flaps in the protective housing.

Press the lock button (1).

Twist off the fastening screw (2) in the centre of the saw

blade.

Replace the saw blade.

Attention! The equalization socket must be positioned! Attention! Observe the drive

motor‘s direction or rotation!

Turn the fastening screw (2) tight again.

4

Care and Maintenance

The orbital circular saw is largely maintenance free.
The lubrication for the anti-friction bearings and the gearbox is sufficient for the life of the machi-
ne.
The motor housing must be opened only by an authorized service facility!
The entire machine, especially the rollers, must be cleaned with compressed air after every use.

Wear safety glasses!

5

Accessories

The relevant accessories can be found from page 92 onwards.

6

Disposal

Components of the unit are recyclable material and should be put to recycling. For this purpose

registered and certified recycling companies are available. For an environmentalfriendly disposal of

the non-recyclable parts (e.g. electronic waste) please contact your local waste disposal authority.
For EU countries only:

Do not dispose of electric tools with domestic waste. In accordance with European Direc-

tive 2012/19/EC on waste electrical and electronic equipment and its implementation as

national law, electric tools that are no longer serviceable must be collected separately and

utilised for environmentally compatible recycling.