Chill BEV-V iNSTAllATiON iNSTrUCTiONS (P/N 9700924)

1-877-392-7836 Fax: 630-784-1000

Page 2 of 2

P/N 1011074 Rev. B 11/10

Manifold Assembly to re-route Cold Plate

Melt Water From Tray

This manifold assembly only applies to cold plate drink water

dispensers that have the melt water drain lines emptying into

the soda overflow tray. For proper installation of the BEV-V, it is

necessary to re-route the cold plate drain lines underneath the

dispenser and into the BEV-V drain water inlet.

ICE

COLD PLATE

DRINK DISPENSER

Syrup Lines

CO

2

Water

Lines

Metal Cold Plate

Drain Nipples

Soda Overflow

Trough

Cold Plate

Cold-Plate Drain Water

To BEV-V

Drain Water Inlet

Figure 3. remove Tubing From Dispenser

Figure 4. Manifold Construction

SUGGESTED MATERIALS NEEDED:

• (2) 1/2” barbed tubing elbows

• (1) 1/2” barbed tubing T connector

• 6 feet 1/2” ID vinyl tubing

• (1) 1/2” tubing clamps

• (2) 1/2” L-shaped tubing turndowns as supplied with some

dispensers

1. Remove the front service panel to gain access to the cold

plate drain line outlets.

2. Remove all existing tubing from the exit points on the cold

plate, as shown in Figure 3.

3. Construct a manifold as shown in Figure 4 to re-route the

cold plate melt water under the dispenser, following the

syrup lines, and under the cabinet to be attached to the

BEV-V drain water inlet.

4. Use tubing clamps to secure any tubing connections.

3. Connect the cold plate drain line to the Drain Water Inlet

on the BEV-V unit using vinyl tubing or PVC pipe.

NOTE: if using vinyl tubing, make sure there are no pinches

or kinks in the tubing.
NOTE: The cold plate drain line should be insulated to keep

water as cold as possible before it enters the unit and to

prevent condensation.
NOTE: Because the cold plate drain line is gravity fed, you

should minimize any obstructions to the flow in the tubing.
4. Turn off the fresh water supply valve.
5. Turn off or unplug the carbonator.
6. Relieve the line pressure by depressing the soda valve.
7. Locate the filtered CO2 water line from the carbonator

and connect the line to the BEV-V CO2 Water Inlet.

8. Connect the pre-chilled BEV-V CO2 Water Outlet to the

cold plate with an insulated line.

9. Turn on the fresh water supply and the carbonator.
10. Check for any water leaks.