A.J. Antunes & Co HLC 8513230063 User Manual

Hlc installation information, Dimensions, Wiring diagram operation

Advertising
background image

1-630-784-1000 Fax: 630-784-1651

Page 1 of 4

P/N 1011090 06/10

1-800-253-2991

A. J. ANTUNES & CO. www.ajantunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188

Dimensions

IMPORTANT

Please read these instructions carefully to assure

correct installation. Prior to being put into opera-

tion, check all wiring and function of the unit.

HLC Installation Information

Wiring Diagram

Operation

When power is applied, the high limit relay will energize

into the normally closed position. If the high limit set point

is exceeded then the relay will de-energize opening the

circuit. The high limit relay can only be reset when the

temperature has dropped below the set point and the

manual reset button (on the front label) is depressed. The

high limit has a visual alarm LED, which is located in the

upper right corner.
Fault Indication: When the LED is “on”, the unit is

latched and in a safe condition (relay open). It can only

be reset when the fault condition is cleared.
Fault Conditions: Over temperature compared to

set point, open or shorted sensor, or any on-board

component failure.

Connections

Thermistor Input: T1, T2 & T3 (100K ohm @ 25°C)
Power Input: T4 & T5 (24-120 VAC)
High Limit Relay: T6 (N.O), T7 (COM)

Installation

For optimum accuracy, the sensor must be mounted with

a minimum of two feet of cable at the sensor lug end

being exposed to the same temperature as the sensor

lug.

5.12”

(130 mm)

2.56”

(65 mm)

3.47”

(88 mm)

2.97”

(75 mm)

2.47”

(63 mm)

3.02”

(77 mm)

BOTTOM VIEW

FULL ENCLOSURE - OPTIONAL

SIDE VIEW

FULL ENCLOSURE - OPTIONAL

.156”

NOTE: Dimensions are for reference only.

T1

T2

T3

T7

T6

T4

T5

Red T1
Black T2
White T3

Sensor

Input

Voltage

24 VAC

COM N.O.

Output

Relay

T7

T6

T4

T5

120 VAC

Specifications

Sensor Type: 100K Thermistor (Dual) - Length 15 ft.

(4.6 m) Other lengths available upon request.
Accuracy: +/-3ºF of Setpoint
Power Input: 24 VAC, 120 VAC, 60 Hz.
Control Operation: High Limit - Opens on

Temperature Rise

Output Ratings: High Limit - 8 Amp. Max. S.P.S.T. Relay,

240 VAC Max. (Resistive Load)

Adjustable Temperature Range: High Limit: 180º to 300ºF

or 100ºF to 220ºF

Ambient Operating Temperature: -30ºF to 140ºF

(-35ºF to 60ºC)

Connections: 1/4” Quick Connects
Package: Aluminum “C” Bracket

Full Enclosure with Conduit Knockout (optional)

Shipping Weight: 2 lbs. (.9 kg)