A.J. Antunes & Co TCE 8253420060 User Manual

Tce installation information, Dimensions panel cutout panel installation, Specifications

Advertising
background image

A. J. ANTUNES & CO. www.ajantunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188

Dimensions

Panel Cutout

Panel Installation

IMPORTANT

Please read these instructions carefully to assure

correct installation. This equipment must be

installed by a licensed electrician. Prior to being

put into operation, check all wiring and function of

the unit.

TCE Installation Information

Specifications

Sensor Type: Thermocouple (Type J or K)
Accuracy: 1% Full Scale ± LSD
Power: 12 VAC/DC, 24 VAC, 115 VAC, 230 VAC, 50/60 Hz.
Controls: On/Off
Output: 3A Relay, Standard (Resistive Load) or

12-16 VDC @ 30 mA
Temperature Range: 50º to 990ºF (10ºC to 530ºC)
Ambient Operating Temperature: -30ºF to 140ºF

(-34ºF to 60ºC)

Ambient Storage Temperature: -40ºF to 180ºF

(-40ºF to 82ºC)

Connections: Screw Terminal
Set Point Adjustment: External Knob or Recessed

Screw Drive Adjustment
Display: 3-Digit LED (0.56” Ht.)
Package: 1/8 DIN Panel Mount Anodized Aluminum Case
Shipping Weight: 2 lbs. (.9 kg)

4.3”

(109 mm)

2.11”

(54 mm)

4.27”

(108 mm)

3.57”

(91 mm)

1.72”

(44 mm)

0.63”

(16 mm)

4.17”

(106 mm)

TCE Side View

Panel Knockout: 1.77” Ht. x 3.62” Wd. (45 mm x 92 mm)

NOTE: Dimensions are for reference only.

3.62”

1.77”

1-630-784-1000 Fax: 630-784-1651

Page 1 of 4

P/N 1011092 Rev. A 11/11

1-800-253-2991

Panel Locking Bars

and 6-32 Screws

Panel

Insert the unit into the panel from the front.

Secure in place with the two locking bars and

screws provided with the unit.