A.J. Antunes & Co DFL 8743130044 User Manual

Dfl installation information, Dimensions wiring diagram, Specifications

Advertising
background image

A. J. ANTUNES & CO. www.ajantunes.com 180 Kehoe Blvd., Carol Stream, Illinois 60188

Dimensions

Wiring Diagram

IMPORTANT

Please read these instructions carefully to assure

correct installation. This equipment must be

installed by a licensed electrician. Prior to being

put into operation, check all wiring and function of

the unit.

DFL Installation Information

Specifications

Sensor: Thermistor, Length 10 Ft. (3 m)
Accuracy: +/-3% of Set Point
Power Input: 24 VAC; 120 VAC, 230 VAC (Optional),

60 Hz.

Control Operation: Low Temperature - Closes on Rise

High Temperature - Opens on Rise

Output Ratings: Two - S.P.S.T. Relays, N.O.,

230 VAC Load

15 Amps @ 120 VAC

(Resistive Load)

SPDT (Optional)

Temperature Range: Fan: 80ºF to 120ºF (25ºC to 50ºC)

High Limit: 150ºF to 300ºF (65ºC to 145ºC)

Differential Adjustment Range:

Fan: 5ºF to 50ºF

High Limit: 1ºF to 15ºF

Operating Temperature: -30º to 140ºF (-35º to 60ºC)
Connections: 1/4” Quick Connects

6” Wire Leads (optional)

Enclosure: Aluminum 5.12” Ht. x 5.9” Wd. x 3.10” Dp.

“C” Bracket, Open Board

Enclosure w/Conduit Knockout (optional)

Shipping Weight: 2 lbs. (.9 kg)

Connections

Thermistor Inputs: (100 kohm @ 25°C)
Fan: T7 & T8
High Limit: T4 & T5 (optional)
Power Input: 24 VAC (optional 120 or 230 VAC)
Vin: T3 & T4
Fan Relay: N.O. & COM. On relay body (optional N.C.)
High Limit Relay: N.O. & COM. On relay body (optional
N.C.)

1-630-784-1000 Fax: 630-784-1651

Page 1 of 4

P/N 1011096 06/10

1-800-253-2991

808000135

415

2.56”

(65 mm)

5.12”

(130 mm)

Ø.187”
(2 PL'S)

40

MODEL DFL

50

10

°F

HYS

110

40

FAN

120

°C

80

°F

30

20

30

25

90

35

50

45

FAN

100

85

95

65

°F

150

170

75

°C

300

ALARM

250

270

125

145

135

105

115

190

HIGH LIMIT

230

210

5.430”

(138 mm)

5.93”

(151 mm)

3.10”

(79 mm)

808000135

415

2.56”

(65 mm)

5.12”

(130 mm)

Ø.187”
(2 PL'S)

40

MODEL DFL

50

10

°F

HYS

110

40

FAN

120

°C

80

°F

30

20

30

25

90

35

50

45

FAN

100

85

95

65

°F

150

170

75

°C

300

ALARM

250

270

125

145

135

105

115

190

HIGH LIMIT

230

210

5.430”

(138 mm)

5.93”

(151 mm)

3.10”

(79 mm)

NOTE: Dimensions are for reference only.

Sensor
Input

T7
T8

Sensor

Input

T4

T5

High

Limit
Relay

N.C.

COM

N.O.

Fan

Relay

N.C.

COM

N.O.

Vin

T3

T2

DFL

System Shutdown

Over Temperature
Contacts

Fan

Control
Contacts

Input Power

(24 VAC)

FAN

FAN

HIGH

LIMIT

TRANSFORMER

120/230 VAC

to 24 VAC

120/130 VAC

(Neutral)

120/230 VAC

(Hot)

Temperature Sensors

Advertising
This manual is related to the following products: